Check the function of the residual current circuit breaker (RCCB) by pressing the test button
"T". This test does not replace the measurement for resistance earthing (RE) or proper
condition testing for the protective earth conductor.
NOTE
Note that you must perform the above test for each RCCB/MCB of the charging station.
Depending on the configuration of the charging station, one charging station comprises
several RCCB/MCBs. According to national installation regulations, you must document the
respective tests carried out on RCCB/MCBs.
NOTE
You must immediately report any damage to seals, in particular damage to electrical
equipment or wiring, or missing seals or covers to the operator. Shut the unit down.
Inspecting fixed charging cables
Inspect fixed charging cables, charging plugs, and charging plug holders regularly for the
following:
• Damage
• Wear
• Contamination
• Humidity
The operator is responsible for safe operation. Set the inspection intervals in such a way that
safe operation is always guaranteed.
Maintenance of fans and filter mats
In the course of checking the safety equipment, check the function of the fans twice yearly
and replace the filter mats on a preventive basis.
Pollution may be lighter or heavier depending on the place of installation. Adapt the
inspection and replacement interval of the filter mats to the place of installation.
SICHARGE Operating Instructions MID
Operating Instructions, 02/2023, A5E48573001-AF
Maintenance and service
8.2 Maintenance