Figure 4-2  Top view of the foundation
The diagram shows an example of a supply line and branch line.
Shorten all cables to 60 cm above the foundation.
NOTE
HAK option
With the HAK option, the foundation and cable routing are different than shown in this
figure. You can find the foundation and reinforcement plan here
(https://support.industry.siemens.com/cs/ww/de/view/109780588).
NOTE
Ethernet interface version
For the version with Ethernet interface, you require an additional empty tube or corrugated
tube for the network cable. The network cable category Cat5 or higher is laid to the charging
station in this empty pipe or corrugated pipe.
Shorten the network cable to 60 cm above the foundation.
SICHARGE Operating Instructions MID
Operating Instructions, 02/2023, A5E48573001-AF
Mounting/assembly
4.3 Assembly procedure