Connector lock fault
Message frame text Charging station ⇒ Backend: ConnectorLockFailure
Message frame text Backend ⇒ Charging station: Faulted
Component: Charging point 1 or 2
Status LED: Flashes red 5x
Description
Connector lock error
Meter fault
Message frame text Charging station ⇒ Backend: PowerMeterFailure
Message frame text Backend ⇒ Charging station: Faulted
Component: Charging point 1 or 2
Status LED: Flashes red 6x
Description
Meter error
Undervoltage fault
Message frame text Charging station ⇒ Backend: UnderVoltage
Message frame text Backend ⇒ Charging station: Faulted
Component: Charging point 1 or 2
Status LED: Flashes red 6x
Description
Undervoltage detected
Fault: Mode 3 error
Message frame text Charging station ⇒ Backend: OtherError (EVSEInitializationError)
Message frame text Backend ⇒ Charging station: Faulted
Component: Charging point 1 or 2
SICHARGE Operating Instructions MID
Operating Instructions, 02/2023, A5E48573001-AF
Cause
The locking mechanism is blocked by the
cable connector.
The locking mechanism is mechanically
blocked or broken.
Cause
The meter is incorrectly wired.
The meter is incorrectly configured.
Cause
The voltage along the cable is below
207 V.
7.2 Service technician faults
Solution
Remove the plug from the socket.
Check the locking mechanism. Remove
the foreign objects or replace the locking
mechanism if necessary.
Solution
Check the wiring.
Check the configuration.
Solution
Check the power supply.
The voltage (L1 ... L3) is shown in the
notification area of the message on the
display.
Faults
79