Adjusting speed setting signal
To provide frequency reference by analog input of control circuit terminal FR or
FC, the relationship between analog input and frequency reference can be set.
MAX. OUTPUT FREQUENCY
GAIN
100
MAX. OUTPUT FREQUENCY
BIAS
100
• Frequency reference gain (n41)
The analog input voltage value for the max (10V). output frequency (n09)
can be set in units of 1% (max. output frequency n09=100%)
Factory setting : 100%
*
• Frequency reference bias (n42)
The frequency reference provided when analog input is 0V (4mA or 0mA)
can be set in units of 1%. (max. output frequency n09=100%)
Factory setting : 0%
*
Typical Setting
• To operate the inverter with frequency reference of 0% to 100% at 0 to 5V
input
MAX. FREQUENCY (100%)
FREQURNCY REFERNCE
0V
10V
(4mA)
(20mA)
(0mA)
(20mA)
0%
0V
Gain n41 = 200
Bias n42 = 0
( ) indicates the value when current
reference input is selected.
5V
10V
45