Omron VS mini J7 User Manual page 102

Compact general purpose inverter
Hide thumbs Also See for VS mini J7:
Table of Contents

Advertisement

Voltage Class
Model
CIMR-J7 * Z????
Motor Overload
Protection
Instantaneous
Overcurrent
Overload
Overvoltage
Undervoltage
Momentary Power
Loss
Cooling Fin Overheat
Stall Prevention Level
Cooling Fan Fault
Ground Fault
Power Charge
Indication
Multi-function
Multi-function
Standard Functions
*
Minimum permissible load: 5VDC, 10mA (as reference value)
102
3-
40P2
40P4
phase
Electronic thermal overload relay
Motor coasts to a stop at approx. 200% of inverter rated
current
Motor coasts to a stop after 1 minute at 150% of inverter
rated output current
Motor coasts to a stop if DC bus voltage exceed 820V
Stops when DC bus voltage is approx. 400V or less
Following items are selectable : Not provided (stops if
power loss is 15ms or longer), continuous operation if
power loss is approx. 0.5s or shorter, continuous operation
Protected by electronic circuit
Can be set to individual levels during accel / decel,
provided / not provided available during coast to a stop
Protected by electronic circuit (fan look detection)
Protected by electronic circuit (rated output current level)
Charge LED is provided.
ON until the DC bus voltage becomes 50V or less.
Four of the following input signals are selectable:
Reverse run (3-wire sequence), fault reset,
external fault (NO / NC contact input), multi-step speed
operation, Jog command, accel / decel time select.
external baseblock (NO / NC contact input), speed search
Input
command, accel / decel hold command, LOCAL / REMOTE
selection, communication / control circuit terminal selection,
emergency stop fault emergency stop alarm
Following output signals are selectable (1 NO / NC contact
output,) :
Fault, running, zero speed, at frequency, frequency
detection (output frequency à or Ä set value), during
*
Output
overtorque detection, minor error, during baseblock,
operation mode, inverter run ready, during fault retry,
during UV, during speed search, data output through
communication
Full-range automatic torque boost, slip compensation,
DC injection braking current / time at start/stop
frequency reference bias /gain, frequency reference with
built-in potentiometer, constant copy, [MEMOBUS
communications (RS-485/422, max. 19.2K bps) (optional) ]
400V 3-phase
40P7
41P5
42P2
43P0
44P0