Standard Wiring

SHORT-CIRCUIT BAR*
L1
L2
FOR SINGLE-PHASE,
USE R/L1 AND S/L2.
L3
FORWARD
RUN/STOP
REVERSE
RUN/STOP
FAULT RESET
EXTERNAL FAULT
MULTI-
(NO CONTACT)
FUNCTION
MULTI-STEP
INPUT
SPEED REF. 1
2kΩ
FREQUENCY
REF.
: Only basic insulation (Protective class 1, overvoltage categoly 2) is provided for the
control circuit terminals. Additional insulation may be necessary in the end product
to conform to CE requirements.
* Short-circuit bar should be removed when connecting DC reactor.
† Minimum permissible load: 5VDC, 10mA (as reference value)
104
DC REACTOR
(OPTION)
U
MCCB
2
R/L1
S/L2
T/L3
S1
S2
S3
S4
S5
SC
SHIELDED CONNECTION
TERMINAL
SPEED REFERENCE PULSE TRAIN
(30kHz MAX.)
FREQUENCY SETTING POWER SUPPLY
FS
( 12V 20mA)
FR
SPEED FREQUENCY REFERENCE
P
0 TO 10V (20kΩ) OR
P
FC
4 to 20mA / 0 to 20mA (250Ω)
0V
DIGITAL OPERATOR
FREQUENCY
SETTING
VOLUME
Shielded
X
1
U/T1
V/T2
W/T3
MA
MB
MC
AM
Twisted-pair wires
P
IM
MULTI-FUNCTION †
OUTPUT
RUNNING
250VAC 1A OR LESS
30VDC 1A OR LESS
ANALOG MONITOR
P
FM
OUTPUT
AC
0 TO 10VDC (2mA)
OUTPUT FREQUENCY