Max; Connection Using Multiple Dcs-Lan Chains Simultaneously; Connection Using Jb 6104 Junction; Box - Shure DCS 6000 User Manual

Hide thumbs Also See for DCS 6000:
Table of Contents

Advertisement

DIS Digital Conference System
The following table shows the maximum number
5.3.2

Connection using multiple DCS-LAN chains simultaneously

of units, which can be connected to the DCS-LAN
using multiple chain outputs simultaneously.
Note: If only one chain is used the information in section
'5.3.1 Connection using only one DCS-LAN chain' must be
used.
5.3.2.1
DC 6120 P, DC 6190 P or DM 6680
P Conference Units
Length of
Length of inter
Feeding Cable
connecting Cable
10 m
1 m
30 m
1 m
50 m
1 m
100 m
1 m
150 m
1 m
10 m
2 m
30 m
2 m
50 m
2 m
100 m
2 m
150 m
2 m
Figure 5.3-I
This following table's shows conference units
5.3.3
Connection using JB 6104 Junction Box
connected to JB 6104 Junction Boxes with 3 m
cables between each Junction Box.
*
Connect only one unit to each output of a JB 6104
Important:
*
Use maximum 10 m cable from JB 6104 to the
conference unit
5.3.3.1
DC 6120 P, DC 6190 P or DM 6680
P Conference Units, two units per

box

Length of
Length of
Feeding
Cable
Cable
between
each JB 6104
10 m
3 m
30 m
3 m
50 m
3 m
100 m
3 m
150 m
3 m
Figure 5.3-K
DC 6120 P, DC 6190 P or DM 6680 P
Conference Unit connected using JB 6104
Junction Box, using only two outputs connection
two unit
Total cable
Max. number
length
of units using
two outputs
2x32 m
2x23
2x51 m
2x22
2x70 m
2x21
2x117 m
2x18
2x164 m
2x15
2x54 m
2x23
2x72 m
2x22
2x88 m
2x20
2x132 m
2x17
2x176 m
2x14
Total
Number of
cable
JB 6104
number of
length
(two outputs
DC 61xxP
in use)
61 m
18
75 m
16
89 m
14
127 m
10
168 m
7
User Manual CU 6110 rev A.docx
5.3.2.2
Length of
Feeding
Cable
10 m
30 m
50 m
100 m
150 m
10 m
30 m
50 m
100 m
150 m
Figure 5.3-J
5.3.3.2
Length of
Feeding
Cable
10 m
30 m
50 m
100 m
150 m

Max.

Figure 5.3-L
36
32
28
20
14
DC 6990 P Conference Units
Length of inter
Total cable
connecting Cable
length
1 m
2x34 m
1 m
2x43 m
1 m
2x62 m
1 m
2x110 m
1 m
2x158 m
2 m
2x36 m
2 m
2x54 m
2 m
2x90 m
2 m
2x118 m
2 m
2x164 m
DC 6120 P, DC 6190 P or DM 6680
P Conference Units, four units
per box
Length of
Total
Number of
Cable
cable
JB 6104
between
length
(four outputs
each JB 6104
in use)
3 m
40 m
3 m
57 m
3 m
74 m
3 m
115 m
3 m
159 m
DC 6120 P, DC 6190 P or DM 6680 P
Conference Unit connected using JB 6104
Junction Box, using all four outputs connecting
four unit
User Manual
Max. number of
DC 6990 P using
two outputs
2x15
2x14
2x13
2x11
2x9
2x14
2x13
2x12
2x10
2x8
Max.
number of
DC 61xxP
11
44
10
40
9
36
6
25
4
16
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu 6110 central unit

Table of Contents