3.3.2. Noise Reduction Level (LEVEL)
Set the strength of NR.
Default: AUTO
Menu
Value
Item
AUTO
LOW
LEVEL
MID
HIGH
Table 6. NOISE REDUCTION - LEVEL
Automatically control the strength of NR.
Set the strength of NR to LOW.
The noise increases when imaging a dark subject
comparing with HIGH/MID, but the after-image will be
less.
Set the strength of NR to MID.
The noise and after-image is about medium between
LOW/HIGH.
Set the strength of NR to HIGH.
The noise decreases when imaging a dark subject
comparing with LOW/MID, but the after-image will be
obvious.
Description