Table 1. The Max. and Min. the Shutter Speed of Each CVBS Format
Max. & Min. of the Shutter Speed (sec.)
CVBS Format
(AE MODE=AUTO)
NTSC/EIA
1/60 - 1/10000
PAL/CCIR
1/50 - 1/10000
SHUT FIX
Gain automatically controls the brightness of the subject but the shutter speed is
fixed.
MANUAL
The shutter speed (including SENS UP) and gain is fixed.

3.1.2. SHUTTER

Set the shutter speed while the AE MODE is SHUT FIX or MANUAL. The configurable
shutter speed is changed in accordance with the NTSC/EIA,PAL/CCIR version
(Table 2).
Table 2. The Configurable Shutter Speed for Each CVBS Format
Configurable Shutter Speed (sec.)
CVBS Format
(AE MODE=SHUT FIX/MANUAL)
1/60, 1/120, 1/180, 1/240,
NTSC/EIA
1/300, 1/500, 1/1000, 1/2000,
1/5000, 1/10000
1/50, 1/100, 1/150, 1/200,
PAL/CCIR
1/250, 1/500, 1/1000, 1/2000,
1/5000, 1/10000

3.1.3. GAIN

Set the gain while the AE MODE is MANUAL.
The configurable gain is 0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65 and
72[dB].