Lauda Viscotemp 15 G Operation Manual page 94

Table of Contents

Advertisement

Code
6XX Switch contacts
1
CAN receive overf
2
Watchdog Reset
9
Unknown Modul
10
SW Contr. too old
11
SW safety too old
12
SW command too old
13
SW cool too old
14
SW analog too old
15
SW serial too old
16
SW contact old
17
SW Valve 0 old
18
SW Valve 1 old
19
SW Valve 2 old
20
SW Valve 3 old
21
SW Valve 4 old
26
SW HTC old
27
SW Ext Pt100 old
Code
17XX Pt100/LiBus Module
1
CAN receive overf
2
Watchdog Reset
3
Ext_Pt_short
7
Invalid Parameter
8
CAN system
9
Unknown Modul
10
SW Contr. too old
11
SW safety too old
12
SW command too old
13
SW cool too old
14
SW analog too old
15
SW serial too old
16
SW contact old
17
SW Valve 0 old
18
SW Valve 1 old
19
SW Valve 2 old
20
SW Valve 3 old
21
SW Valve 4 old
26
SW HTC old
27
SW Ext Pt100 old
94 / 134
Meaning
Overflow during CAN reception
Watchdog reset
Unknown module connected
Software version of control panel too old
Software version of protection too old
Software version of command remote
control unit too old
Software version of cooling module too old
Software version of analog too old
Software version of RS 232 too old
Software version of contact module too old
Software version of solenoid valve 0 too old
Software version of solenoid valve 1 too old
Software version of solenoid valve 2 too old
Software version of solenoid valve 3 too old
Software version of solenoid valve 4 too old
Software version of high temperature cooler
too old
Software version of external Pt100 too old
Meaning
Overflow during CAN reception
Watchdog reset
Line short on external t100
Inadmissible parameter in memory
Problem during internal data interchange
Unknown module connected
Software version of control panel too old
Software version of protection too old
Software version of command remote control unit too old
Software version of cooling module too old
Software version of analog too old
Software version of RS 232 too old
Software version of contact module too old
Software version of solenoid valve 0 too old
Software version of solenoid valve 1 too old
Software version of solenoid valve 2 too old
Software version of solenoid valve 3 too old
Software version of solenoid valve 4 too old
Software version of high temperature cooler too old
Software version of external Pt100 too old
ECO Gold
Code
7, 8, 9, 10, 11,
16XX Solenoid valve
1
CAN receive overf
2
Watchdog Reset
3
No cooling liquid
6
no unfill liquid too hot
9
Unknown Modul
10
SW Contr. too old
11
SW safety too old
12
SW command too old
13
SW cool too old
14
SW analog too old
15
SW serial too old
16
SW contact old
17
SW Valve 0 old
18
SW Valve 1 old
19
SW Valve 2 old
20
SW Valve 3 old
21
SW Valve 4 old
26
SW HTC old
27
SW Ext Pt100 old
Meaning
Overflow during CAN reception
Watchdog reset
No cooling liquid present (HTC)
No draining, because bath temperature is
too hot (HTC)
Unknown module connected
Software version of control panel too old
Software version of protection too old
Software version of command remote
control unit too old
Software version of cooling module too old
Software version of analog too old
Software version of RS 232 too old
Software version of contact module too old
Software version of solenoid valve 0 too old
Software version of solenoid valve 1 too old
Software version of solenoid valve 2 too old
Software version of solenoid valve 3 too old
Software version of solenoid valve 4 too old
Software version of high temperature cooler
too old
Software version of external Pt100 too old
09/2021