Rs 232/485 Interface Module; Connecting Lead And Interface Test Rs 232 - Lauda Viscotemp 15 G Operation Manual

Table of Contents

Advertisement

Connection of analogue inputs and outputs
A six-pole round connector with screw lock and contact assignment according to DIN EN 60130-9 or IEC 130-9 are
required.
A suitable coupling plug is obtainable under the catalogue no. EQS 057.
View of socket (front) or solder side of plug:
Socket 74S
Note: Only use screened connecting leads and connect the screen to the plug housing.
19.3

RS 232/485 interface module

19.3.1

Connecting lead and interface test RS 232

Signal
R x D
T x D
DTR
Signal Ground
DSR
RTS
CTS
 with hardware handshake: On connecting a thermostat to the PC use a 1:1 and not a null-modem cable.
 without hardware handshake: Set the operating mode on the PC "without hardware handshake".
 Use screened leads and connect screen to plug case.
 The wires are electrically isolated from the rest of the electronics.
 Non-assigned pins should not be connected.
The RS 232 interface can be checked in a simple way with a connected PC running Microsoft Windows operating sys-
®
tem. With Windows
95/98/NT/XP using the program "HyperTerminal".
09/2021
RS 232/485 Interface Module (LAUDA catalogue no. LRZ 913) with
nine-pole SUB-D socket. Electrically isolated using optocouplers. With the
LAUDA instruction set, extensively compatible to Ecoline, Proline and
Integral series.
The RS 232 interface can be connected directly to the PC with a 1:1 con-
nected cable (catalogue no. EKS 037, 2 m cable and EKS 057, 5 m cable).
Computer
9-pole Sub-D socket
2
2
3
3
4
5
5
6
7
8
Contact 1
Output 1
Contact 2
Output 2
Contact 3
0 V reference potential
Contact 4
Input 1
Contact 5
+20 V (max. 0.1 A)
Contact 6
Input 2
25-pole Sub-D socket
3
3
2
2
20
7
7
6
4
5
ECO Gold
Thermostat
9-pole Sub-D socket
2
2
3
3
4
5
5
6
7
8
113 / 134
Signal
T x D
R x D
DSR
Signal Ground
DTR
CTS
RTS