Rack 1: Do - Rockwell Automation ICSTT-RM280N-EN-P Manual

Trusted tmr 24 vdc digital output module - 40 channel
Table of Contents

Advertisement

3. Application
Rack
I/O Board
6
DISCREP
7
HKEEPING
8
INFO
There are two OEM parameters included in the first rack (DO Board). These OEM
parameters define the primary Module position; declaring the Module's chassis and slot
location. There is no need to define the secondary Module position within the IEC 61131
TOOLSET. Where systems may be required to start-up with Modules in the secondary
position as the Active Module, e.g. primary Module is not installed when application is
started, the secondary Module's position should be declared in the Module definition of the
System Configuration Manager.
OEM Parameter
TICS_CHASSIS
TICS_SLOT

3.2.1. Rack 1: DO

This board provides the connection to the logical output control signal for each of the field
outputs.
16
Description
Channel Discrepancy
Housekeeping Registers
I/O Module Information
Table 3 Complex Equipment Definition
Description
The number of the Trusted
Chassis where the Primary
I/O Module is installed
The slot number in the
Chassis where the Primary
I/O Module is installed
Table 4 OEM Parameters
Channel
Description
1
Field output channel 1 logical state
2
Field output channel 2 logical state
40
Field output channel 40 logical state
Issue 14
Trusted TMR 24Vdc Digital Output Module – 40 Channel
Data Type
Integer
Integer
Integer
Notes
The Trusted Controller Chassis is 1, and
Trusted Expander Chassis are 2 to 15.
The I/O Module slots in the Trusted
Controller Chassis are numbered from 1 to 8.
The I/O Module slots in the Trusted Expander
Chassis are numbered from 1 to 12.
Rockwell Automation Publication ICSTT-RM280N-EN-P
Direction
No. of
Channels
In
3
In
57
In
11