Lenovo 7Y45 Instructions Manual page 106

Messages and codes reference
Hide thumbs Also See for 7Y45:
Table of Contents

Advertisement

1. Perform virtual system reseat or A/C power cycle.
2. If the error persists, remove A/C power and any recently installed components.
3. If the system successfully powers on, complete the following steps:
a. Check the Server Proven website (http://www.lenovo.com/us/en/serverproven/index.shtml) to
make sure that recently installed components are compatible with the system.
b. Inspect the previously installed components for physical damage and fix it.
c. If the system does not successfully power on or if this is not the first occurrence of this problem,
go to step 4.
4. If the system has stand-by power, collect Service Data logs.
5. Contact Lenovo Support.
• FQXSPPW0101J: Redundancy Degraded for [RedundancySetElementName] has asserted.
This message is for the use case when Redundancy Degraded has asserted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0804
User Action:
Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system.
• FQXSPPW0104J: Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has asserted.
This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded or
Fully Redundant to Non-redundant:Sufficient.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0806
User Action:
Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system.
• FQXSPPW0110M: Non-redundant:Insufficient Resources for [RedundancySetElementName] has
asserted.
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Redundant Power Supply
SNMP Trap ID: 9
CIM Prefix: PLAT CIM ID: 0810