User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or UEFI firmware update that applies to
this error.
2. Reboot system.
3. If problem persists, collect Service Data log.
4. Contact Lenovo Support.
• FQXSPPU2001I: An Over-Temperature Condition has been removed on [ProcessorElementName].
This message is for the use case when an implementation has detected a Over-Temperature Condition
has been Removed for Processor.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0037
User Action:
Information only; no action is required
• FQXSPPU2002I: The Processor [ProcessorElementName] is no longer operating in a Degraded
State.
This message is for the use case when an implementation has detected a Processor is no longer running
in the Degraded state.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - CPU
SNMP Trap ID: 42
CIM Prefix: PLAT CIM ID: 0039
User Action:
Information only; no action is required
• FQXSPPW0001I: [PowerSupplyElementName] has been added to container
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Power Supply has been added.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0084
User Action:
Information only; no action is required
• FQXSPPW0002L: [PowerSupplyElementName] has Failed.
This message is for the use case when an implementation has detected a Power Supply has failed.