Lenovo 7D7M Reference page 136

Messages and codes reference
Table of Contents

Advertisement

Table 3. Events organized by severity (continued)
Message String
Event ID
FQXSFIO0025I
An error has been detected by the IIO on processor [arg1]. The index
of the IIO stack is [arg2]. The type of IIO Internal Error is [arg3]. Please
check error logs for additional downstream device error data.
FQXSFIO0041J
PCIe Leaky Bucket Event : [arg1] occurred at Segment [arg2] Bus
[arg3] Device [arg4] Function [arg5]. The physical [arg6] number is
[arg7].
FQXSFMA0016M
Memory spare copy failed. [arg1]
FQXSFMA0026G
Multi-bit CE occurred on DIMM [arg1], need to restart the system for
DIMM Self-healing to attempt post package repair (PPR)
FQXSFMA0027M
DIMM [arg1] Self-healing, attempt post package repair (PPR) failed at
Rank [arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6].
[arg7]
FQXSFMA0028M
DIMM [arg1] Self-healing, attempt post package repair (PPR)
exceeded DIMM level threshold [arg2] at Rank [arg3] Sub Rank [arg4]
Bank [arg5] Row [arg6] on Device [arg7]. [arg8]
FQXSFMA0030K
Intel Optane PMEM [arg1] Percentage Remaining is less than [arg2]%
and still functioning.
FQXSFMA0031K
Intel Optane PMEM [arg1] has reached 1% remaining spares block
and still functioning.
FQXSFMA0033M
Intel Optane PMEM persistent memory interleave set has [arg1]
PMEMs(DIMM [arg2]), [arg3] DIMMs' location is not correct.
FQXSFMA0034M
DIMM [arg1] (UID: [arg2]) of Intel Optane PMEM persistent memory
interleave set should be moved to DIMM slot [arg3] in sequence.
FQXSFMA0035M
Intel Optane PMEM interleave set should have [arg1] PMEMs, but
[arg2] PMEMs are missing.
FQXSFMA0036M
DIMM [arg1] (UID: [arg2]) of Intel Optane PMEM persistent memory
interleave set is missing.
FQXSFMA0037G
Intel Optane PMEM interleave set (DIMM [arg1]) is migrated from
another system (Platform ID: [arg2]), these migrated PMEMs are not
supported nor warranted in this system.
FQXSFMA0038K
All Intel Optane PMEMs could not be auto unlocked because of no
passphrase.
FQXSFMA0039K
One or more Intel Optane PMEMs could not be auto unlocked
because of invalid passphrase.
FQXSFMA0040K
Invalid Intel Optane PMEM configuration detected. Please verify
PMEM configuration is valid.
FQXSFMA0041K
Near Memory/Far Memory ratio (1:[arg1].[arg2]) for Intel Optane
PMEM configuration is not in recommended range (1:[arg3] - 1:[arg4]).
FQXSFMA0047M
SPD CRC checking failed on DIMM [arg1]. [arg2]
FQXSFMA0048M
DIMM [arg1] has been disabled due to PMIC failure during POST.
[arg2]
FQXSFMA0050M
EpRC PFA threshlod limit has been exceed on DIMM[arg1] RANK0
DRAM[arg2] RANK1 DRAM[arg3].[arg4]
132
ThinkSystem SD650 V3 / ThinkSystem SD650-I V3 Neptune DWC Trays and DW612S Neptune DWC Enclosure Messages and
Codes Reference
Severity
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning

Advertisement