2. If the problem still exist then replace the adapter.
3. If the problem still exist then contact local service.
• FQXSPIO0010I: A Correctable Bus Error has occurred on bus [SensorElementName].
This message is for the use case when an implementation has detected a Bus Correctable Error.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0238
User Action:
Information only; please correct the error recorded in system log to resolve the error
• FQXSPIO0011N: An Uncorrectable Error has occurred on [SensorElementName].
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0240
User Action:
Check http://support.lenovo.com/ for TECH tips or firmware updates that might correct the error.
1. Make sure that all I/O expansion adapters have correct and matching levels of device drivers and
firmware.
2. Check the event log of XClarity Controller for additional information about failing components.
3. If there are no entries related to the error in the event log, contact Lenovo support
• FQXSPIO0013N: A Fatal Bus Error has occurred on bus [SensorElementName].
This message is for the use case when an implementation has detected a Bus Fatal Error.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0244
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
2. If problem persists, collect Service Data log.
3. Contact Lenovo Support.
• FQXSPIO0014J: Bus [SensorElementName] is operating in a degraded state.
This message is for the use case when an implementation has detected a Bus is Degraded.
48
ThinkSystem SD650 V3 / ThinkSystem SD650-I V3 Neptune DWC Trays and DW612S Neptune DWC Enclosure Messages and
Codes Reference