Lenovo 7D7M Reference page 174

Messages and codes reference
Table of Contents

Advertisement

• FQXSFPU4085I: Host WOL boot order has been changed.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFPW0001L: CMOS has been cleared.
Severity: Warning
User Action:
Complete the following steps:
1. If the CMOS clear was user initiated this event can be safely ignored and no further action is required.
2. If the system was recently installed, moved, or serviced, make sure the battery is properly seated.
3. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
error.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
• FQXSFSM0002N: Boot Permission denied by Management Module: System Halted.
Severity: Warning
User Action:
Complete the following steps:
1. Check XCC logs.
2. Review power policies and system configuration settings in the XCC GUI.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
• FQXSFSM0003N: Timed Out waiting on boot permission from Management Module: System
Halted.
Severity: Warning
User Action:
Complete the following steps:
1. Check XCC logs.
2. Review power policies and system configuration settings in the XCC GUI.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
• FQXSFSM0004M: An XCC communication failure has occurred.
Severity: Warning
User Action:
Complete the following steps:
1. AC cycle the system.
2. Make sure XCC and UEFI FW are operating with same compatible level.
3. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
error.
170
ThinkSystem SD650 V3 / ThinkSystem SD650-I V3 Neptune DWC Trays and DW612S Neptune DWC Enclosure Messages and
Codes Reference