Lenovo 7D7M Reference page 31

Messages and codes reference
Table of Contents

Advertisement

Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Fan Failure
SNMP Trap ID: 11
CIM Prefix: PLAT CIM ID: 0480
User Action:
Complete the following steps:
1. Ensure fans are installed correctly.
2. If fan is installed with issue , please reinstall fan.
3. If the problem still exist, then please contact Lenovo support.
• FQXSPCA0007J: Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted.
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Temperature
SNMP Trap ID: 12
CIM Prefix: PLAT CIM ID: 0490
User Action:
Complete the following steps:
1. Check the event log of system management module and XClarity Controller for any fan or cooling-
related issues or power-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in
place,clean, and correctly installed.
3. Make sure that the room temperature is within operating specifications.
• FQXSPCA0009M: Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted.
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0494
User Action:
Complete the following steps:
1. Ensure the room temporature is within server environmental specification to adjust the temporature.
2. If the problem issue still exist, check XCC Web GUI to check the temporature value is still higher than
system spec.
3. Please contact Lenovo support.
.