Installing the 7044A-82R into a Rack
This section provides information on installing the SuperServer 7044A-82R into a
rack unit. Rack installation requires the use of the optional rackmount kit [CSE-
PT26(B)]. If the 7044A-82R has already been mounted into a rack or if you are
using it as a tower, you can skip ahead to Sections 2-5 and 2-6. There are a
variety of rack units on the market, which may mean the assembly procedure will
differ slightly. The following is a guideline for installing the 7044A-82R into a rack
with the rack rails provided in the rackmount kit. You should also refer to the
installation instructions that came with the rack unit you are using.

Identifying the Sections of the Rack Rails:

The optional 7044A-82R rackmount kit (CSE-PT26 or CSE-PT26B - black) in-
cludes two rack rail assemblies. Each of these assemblies consist of three
sections: an inner fixed chassis rail that secures to the 7044A-82R (A), an outer
fixed rack rail that secures directly to the rack itself (B) and a sliding rail guide
sandwiched between the two, which should remain attached to the fixed rack rail
(see Figure 2-1.) The A and B rails must be detached from each other to install.
Two chassis handles are also included with the rail kit.
To remove the fixed chassis rail (A), pull it out as far as possible - you
should hear a "click" sound as a locking tab emerges from inside the rail
assembly and locks the inner rail. Depress the locking tab to pull the
inner rail completely out. Do this for both assemblies.
Figure 2-1.
Identifying the Sections of the Rack Rails
B
2-4