Front Control Panel - Supero SuperServer 7044A-82R User Manual

Supermicro superserver 7044a-82r: user guide
Table of Contents

Advertisement

6-2

Front Control Panel

The front control panel must be connected to the JF1 connector on the
serverboard to provide you with system status and alarm indications. A
ribbon cable has bundled these wires together to simplify this connection.
Connect the cable from JF1 on the serverboard (making sure the red wire
plugs into pin 1) to the appropriate comnnector on the front control panel
PCB (printed circuit board). Pull all excess cabling over to the control
panel side of the chassis. The LEDs on the control panel inform you of
system status - see Figure 6-2 for details. See Chapter 5 for details on JF1.
Power
HDD
NIC1
NIC2
Overheat/
Fan Fail
Power Fail
Figure 6-2. Front Control Panel LEDs
Indicates power is being supplied to the system.
Indicates IDE device and hard drive activity. On the
SuperServer 7044A-82R, this LED indicates SCSI hard
drive activity when flashing.
Indicates network activity on GLAN Port 1.
Indicates network activity on GLAN Port 2.
When the LED stays on, it Indicates that a CPU over-
heat condition has occured. If the LED blinks, it indi-
cates a possible fan failure.
Indicates a power supply failure.
Chapter 6: Advanced Chassis Setup
6-3