Co-linear direct vent gas fireplaces
Table of Contents

Advertisement

B. CLEARANCES
From unit left & right sides
To flooring under fireplace
Unit top to ceiling
Unit side to adjacent sidewall
From appliance front*
Figure 2B
6" [152]
Top Standoffs
1/2" [13]
The hood must be supported at specific
locations using 1/4-20 UNC threaded rods.
Refer to Section 3 (Threaded Rods)
for requirements.
1/2" [13]
NO COMBUSTIBLE
MATERIAL WITHIN 1" [25]
OF THE SIDE OF
FIREPLACE
COMBUSTIBLE
FRAMING AND
FINISHING MATERIAL
ALLOWED ON THE FACE
OF THE FIREPLACE
BELOW THE BOTTOM
VIEWING EDGE ONLY.
OTHER CLEARANCES:
DO NOT PLACE ON CARPET, VINYL OR SOFT SURFACES.
COMBUSTIBLE FRAMING ALLOWED RIGHT UP TO THE FIREPLACE UNDER THE VIEWING AREA BOTTOM ONLY.
A COMBUSTIBLE MANTEL MAY BE PLACED AT THE TOP OF THE GLASS VIEWING AREA. DO NOT OVERLAP GLASS.
A COMBUSTIBLE HEARTH EXTENSION MAY BE USED AT THE BOTTOM OF GLASS VIEWING. DO NOT OVERLAP GLASS.
* MINIMUM DISTANCE RECOMMENDED FROM FRONT OF APPLIANCE FOR SERVICE ACCESS = 24 IN. [610 mm].
COMBUSTIBLE FINISHING MATERIALS MAY COVER 3" (76) TOP AND BOTTOM BLACK TRIM. DO NOT OVERLAP GLASS
Heat & Glo • FDN-4-PIER, FDN-5-PIER, FDN-6-PIER, FDN-7-PIER Installation Manual • 16400-9803 Rev. o • 4/21
CLEARANCES SHOWN ARE MINIMUM TO COMBUSTIBLES
NON-COMBUSTIBLE FRAMING AND FINISHING MATERIALS ALLOWED RIGHT UP TO THE FIREPLACE.
1/2" [13]
1/2" [13]
Minimum distance recommended
from front of appliance for service access.
NO COMBUSTIBLE
1"
MATERIAL WITHIN 1" [25]
[25]
OF B-VENT FLUE
X3 1/2" [13] Hood Standoffs on each side.
Refer to Section 5 (Non-Combustible Zone)
for more information.
ACCESS PANEL
FRONT AND REAR
Refer to Section 3 (Prepare The Fireplace)
1"
Combustible Framing
[25]
Can be a recess and/or combustible perpendicular wall extending past the face
of the fireplace. Must keep a minimum of 12" from the side glass to a parallel wall
to facilitate easy removal of the glass pane.
Refer to Section 2.A (Pier Dimension diagram)
24" [610]
for more measurements.
NO COMBUSTIBLE MATERIAL
WITHIN 6" [152] OF THE TOP
OF THE FIREPLACE
6" [152]
1/2" [13]
Top Black Trim
NO COMBUSTIBLE
MATERIAL WITHIN
1" [25] OF BACK OF
FIREPLACE
Bottom
Black Trim
1"
0
48"
1"
6" [152] Top Standoffs; shipped flat.
1" [25]
Standoff
25mm
0
122cm
25mm
1/2" [13]
7