Table of Contents

Advertisement

Quick Links

Models:
SUPREME-I30-NZ
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SUPREME-I30-NZ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Heat&Glo SUPREME-I30-NZ

  • Page 1 This appliance is only for use with the type(s) of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 2: Congratulations

    BTUH: 00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial XXXXXXXX XXXXXXXX ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 3: Table Of Contents

    B. Flue Damper........20  = Contains updated information. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 4: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645H 10/15 Page 1 of 2 Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 5 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645H 10/15 Page 2 of 2 Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 6: Listing And Code Approvals

    * The allowable Outlet (Manifold) Gas Pressure ranges are: Natural Gas .80 - .95 kPa and Propane 2.37 - 2.61 kPa. An in-line regulator MUST be installed if the gas pressure exceeds 3.40 kPa. Failure to install a regulator could damage valve. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 7: User Guide

    • Install a switch lock or a wall/remote control with child protection lockout feature. • Keep remote controls out of reach of children. • Never leave children alone near a hot fireplace, whether operating or cooling down. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 8: Clear Space

    3. The control module has safety feature that automatically shuts down the fireplace after 9 hours of continuous operation without receiving a command from the RC300 remote. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 9: Before Lighting Fireplace

    The appliance has a safety feature that automatically shuts down the fireplace after nine hours of continuous operation without receiving a command from the wall switch or optional remote. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 10: Lighting Instructions (Ipi)

    Keep burner and control compartment clean. See installation and operating instruc- Propane Installation code, CSA B149.1. tions accompanying appliance. For additional information on operating your 593-913i Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 11: After Appliance Is Lit

    Some optional control systems available with IPI models may allow pilot flame to continually? remain lit. In a standing pilot system the pilot will always stay on. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 12: Maintenance And Service

    • Carefully set fixed glass assembly in place on appliance. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall decorative front. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 13: Maintenance Tasks-Service Technician

    Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. • Remove all foreign objects. • Verify unobstructed air circulation. Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 14: Installer Guide

    SECTION 5.B AND 11.A SURROUND OR FRONT NOT SHOWN SECTION 2.D AND 8.D. HEARTH EXTENSION GAS LINE (SECTION 9) ACCESS THROUGH EXISTING MASONRY OR WOODBURNING FIREPLACE Figure 4.1 Typical System Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 15: Design And Installation Considerations

    DO NOT use this appliance if any part has been under water. Call a qualified technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 16: Fireplace Size Requirements

    1/4 inch. The original fireplace may never be returned to solid fuel in this condition. The sidewalls and top structure of the firebox may not be altered with the exception of removable baffles and dampers. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 17 **Unit depth is measured to the back of the surround to give the depth needed for installation. In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B). Figure 5.2 Firebox Opening - Standard Surround Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 18: Mantel And Wall Projections

    Combustible facings must not extend behind the insert surround. For non-combustible material specifications refer to section 1.E. Figure 5.4 Mantel Clearances Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 19: Termination Locations

    Over 18/12 to 20/12 (56.3°-59.0°) .......7.5 (2290) Over 20/12 to 21/12 (59.0°-60.3°) .......8.0 (2440) * 3 ft. (910 mm) minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 20: Installation Preparation

    An in-line regulator MUST be installed if the gas pressure exceeds 3.4 kPa. Failure to install a regulator could dam- age valve. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 21: Installing Vent Pipe And Appliance

    VENT PIPE INLET AIR STARTING COLLAR NOTE: TO ACHIEVE OPTIMUM PERFOR- MANCE OF INSERT, MINIMIZE OR AVOID BENDS IN EXHAUST VENT PIPE. STARTING COLLAR BRACKET EXHAUST STARTING COLLAR Figure 8.1 Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 22: Placing, Securing And Leveling The Appliance

    WARNING! Risk of Explosion! Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance could result in property damage or personal injury. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 23: Remote Control

    REAR LEVELING LEGS MAY BE RELOCATED TO LOCATION A OR LOCATION B Figure 8.4 Location of AUX300CE for Remote Control Blower Function - IPI LOCATION A LOCATION B Figure 8.3 Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 24: Installing Adaptor And Termination Cap

    Over 20/12 to 21/12 ..8.0 Over 10/12 to 11/12 ..3.25 * 3 foot minimum in snow regions Figure 8.5 Minimum Height from Roof to Lowest Discharge Opening Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 25 • Depending on the chimney cleanliness, consider using the full length intake so as to lessen the possibility of sense rod contamination and flame rectification issues. Figure 8.7 Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 26: Gas Information

    DMS 53 (1.51 mm) Pilot Injector .023 .014 .014 An in-line regulator MUST be installed if the gas pressure exceeds 3.40 kPa. Failure to install a regulator could damage valve. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 27: Gas Connection

    • In the USA: Reduce burner orifice 4% for each 1000 feet above 2000 feet. • In the CANADA: Reduce burner orifice 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 28: Electrical Information

    WARNING! Risk of Shock or Explosion! DO NOT wire 220/240VAC to the valve or to the appliance wall switch. Incorrect wiring will damage controls. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 29 OPTIONAL ON/OFF WALL SWITCH ORANGE GREEN BLACK (PILOT) (MAIN) BROWN BATTERY PACK - 6V DC 220/240VAC INCOMING POWER GROUND EMC FILTER UNIT GROUND Figure 10.1 IPI Wiring Diagram RC300AU Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 30: Optional Accessories Requirements

    WALL SWITCH 2187-198 GREEN SURROUND (MAIN) SWITCH VALVE OPTIONS NG 2166-302 LP 2166-303 * NOTE: GROUND FROM WIRE HARNESS MUST BE ATTACHED TO UNPAINTED METAL Figure 10.2 Fan Wiring Diagram Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 31: Rem300-Hng-Au Instructions

    The RC300AU is approved for interior installation and should not be used in exterior applications. • Keep remote control out of reach of children. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 32 Figure 10.5. Remote in Housing Figure 10.3. Temperature Scale 5. Close the housing door. See Figure 10.6. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 33 3 steps, timer based, LEARN BUTTON MED and LOW 3 min. ON, 12 min. OFF FAN CORD Figure 10.9. Programming RC300AU AUX 300CE MODULE Figure 10.8 Plug Fan into AUX300CE Module Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 34 Use the SELECT button to select the current Select feature. Menu Use the UP and DOWN arrows to toggle Menu through the menu functions and value selec- Select Select tions in the submenus. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 35 AUX and AUX2 can be activated when the flame is off seconds. from the remote’s OFF mode. When the fireplace is turned back ON the AUX1 and AUX2 settings will be restored to the previous ON setting. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 36 • Rotate the valve 90 degrees to turn off gas supply. NOTICE: No functions will be usable until child lock feature Turn off power to the fireplace (if back-up batteries are is disabled. not installed): • Locate house circuit breaker for fireplace. • Turn off the circuit breaker. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 37 At control module, turn off fireplace by sliding the ON/OFF/RE- Remote control or control MOTE switch to OFF. Warning! Risk of Burns! Fireplace is hot. module failure Use caution when accessing module. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 38: Finishing

    Combustible facings must not extend behind the insert surround. For non-combustible material specifications refer to section 1.E. Figure 11.1 Clearances to Mantels or other Combustibles above Appliance Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 39: Appliance Setup

    • Place lava rock in front of and to the sides of the burner. Figure 12.2 Placement of Embers PLACE LAVA ROCK IN SHADED AREA ONLY Figure 12.1 Placement of Lava Rock Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 40: Install The Log Assembly

    Log #2 (SRV2206-705): Position Log #2 as shown in Figure 3. Mate the slot located on the bottom of Log #2 (Figure 4) with the log pin located on the surface of the burner. Rotate the right end of Log #2 clockwise, until it comes into contact with the grate tine. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 41 Log #6 SRV(2206-706): Position Log #6 as shown in Figure 8. See Figure 7 for additional references. Rest the left end of Log #6 on the flat spot of Log #3. Position the nose of Log #6 on the fork of Log #5. 2206-935C Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 42: Fixed Glass Assembly

    Verify top latches are fully engaged and then fasten the two bottom latches. 3/8 in. 1/2 in. SUPREME-I30-NZ Full Open (10 mm) (13 mm) Figure 12.3 Fixed Glass Assembly Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 43: Troubleshooting

    D. Pilot valve solenoid. Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module. If below 1.5 volts, replace module. If 1.5 volts or greater, replace valve. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 44 Verify continuity with a multi-meter with ohms set at lowest range. Replace pilot if any damage is detected. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 45: Reference Materials

    10-1/16 4-15/16 9-1/2 1-3/4 4-5/8 *Note: Location G on Figure 14.1 is measuring the appliance depth, for installation depth reference Location E on Figure 5.2. Figure 14.1 Appliance Dimensions Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 46: Decorative Fronts And Surrounds

    Surround, 40-1/8 x 27-1/8 x 1 in. deep - Black 1020 x 690 x 25 mm deep - Black Refer to the installation instructions supplied with the doors and the surrounds. Contact dealer for further information. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 47: Optional Accessories

    FIREPLACE STATUS TEMP SETTING THERMOSTAT CHILD LOCK FLAME HEIGHT INDICATOR FAN SPEED TRANSMISSION INDICATOR ADJUSTABLE AUXILIARY LOW BATTERY ADJUSTABLE INDICATOR OUTPUT (ON/OFF) FUNCTION LEVEL INDICATOR ROOM TEMP DISPLAY TIMER DISPLAY/FUNCTION Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 48: Vent Kits Components

    FLEX3-30: One 3 inch (76 mm) flexible liner expands to 30 feet (9.14 m). FLEX-CNCT: Connector kit - 3 inch (76 mm) liner to 3 inch (76 mm) liner, one connector per kit. Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...
  • Page 49: Service Parts

    6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7074035, 7098269, 7258116, 7322819, 7470729, 7726300, 8147240, 9625149 or other U.S. and foreign patents pending. 2000-945D Printed in U.S.A. - Copyright 2018 Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18...

Table of Contents