MAINTENANCE OPERATIONS

During the use of your
the equipment.
I - MAINTENANCE OF THE VALVE (filter cleaning, replacement of membrane)
a
For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www.mytub.co.uk
BCM 350 flushing cistern, you may be required to maintain
VERSO
➋➌
Remove the control panel by lifting it slightly and tilting it forward
Remove the operating screws
Lstening the chassis screws and remove the chassis
Remove the frame as indicated under point VI of the manual
Close the shut-off valve (b) and separated from the float valve (a).
Take out the floater tap
b
Membrane
Unscrew the screws of the tap to take out the membrane
and the filter. Change the membrane and clean the filter
Spare parts:
Membrane: P/N 349513-07
Complete valve: P/N 309503-07
14
Filter