Maintenance - Bristan KN2 SHXAR C Installation Instructions And User Manual

Colonial thermostatic surface mounted mini shower valve with adjustable or rigid riser
Table of Contents

Advertisement

Maintenance

Adjusting the Temperature
The shower valve has been factory set
with equal (balanced) hot and cold
water supply pressures with the hot
water supply at 65ºC.
If your operating conditions are
different from those above, the outlet
water temperature may differ from the
factory setting.
If required the shower valve can be re-
calibrated to suit your own temperature
requirements.
Set the temperature control lever to
maximum and check the temperature
of the water with a thermometer. If the
temperature is not correct, re-calibrate
the shower valve.
1. Turn the lever anti-clockwise to the
maximum temperature position.
2. Remove the handle: unscrew the
Handle
Lever
26
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
cont.
Temperature
Grub
adjusting screw
screw
Cooler
lever, loosen the grub screw using the
hexagonal key and carefully pull the
handle off.
3. Using the hexagonal key, turn the
temperature adjusting screw to alter
the temperature.
• Turn clockwise for a cooler
temperature
• Turn anti-clockwise for a warmer
temperature
Note: This will be the maximum
temperature setting, it is
recommended that the temperature is
set no higher than 43ºC.
4. Once the correct temperature is
achieved, re-attach the handle and
close the valve. Ensure the stop on the
handle is in the correct position
(vertically down), allowing the valve to
turn on anti-clockwise.
5. Tighten the grub screw to lock the
handle in place and screw the lever
into the handle.
Warmer