Maintenance

General Cleaning
Your product has a high quality finish
and should be treated with care to
preserve the visible surfaces. All
surfaces will wear if not cleaned
correctly, the only safe way to clean your
mixer is to wipe with a soft damp cloth.
Stains can be removed using washing
up liquid. All bath cleaning powders and
liquids will damage the surface of your
fitting, even the non-scratch cleaners.
Note: Never use abrasive detergents
or disinfectants or those containing
alcohol, hydrochloric acid or phosphoric
acid.
Cleaning the Cartridge
Before carrying out any maintenance,
turn off the both water supplies or close
any isolating valves.
Remove the cap, loosen the grub screw
using a 2.5mm hexagonal key. Remove
the handle, shroud and cartridge
retaining nut. Remove the cartridge.
Clean the cartridge thoroughly under
cold water to remove any build up of
limescale or debris.
If necessary replace the cartridge using
parts supplied by Bristan only.
Replace the cartridge into the body.
Replace the cartridge retaining nut,
shroud and the handle. Tighten the grub
screw and push fit the cap.
10
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Grub Screw
Handle
2.5 mm hexagonal
key
Cap
Shroud
Cartridge Retaining Nut
Cartridge