Maintenance - Bristan R2 SHXRR C Installation Instructions And User Manual

Regency thermostatic surface mounted shower valve with adjustable or rigid riser
Table of Contents

Advertisement

Maintenance

Adjusting the Temperature
The shower valve has been factory set
with equal (balanced) hot and cold water
supply pressures with the hot water
supply at 65ºC.
If your operating conditions are different
from those above, the outlet water
temperature may differ from the factory
setting.
If required the shower valve can be re-
calibrated to suit your own temperature
requirements.
Set the temperature control lever to
maximum and check the temperature of
the water with a thermometer. If the
temperature is not correct, re-calibrate
the shower valve.
1. Turn the temperature handle anti-
clockwise to the maximum temperature
position.
2. Remove the controls: remove the
indice, loosen the grub screw using the
26
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
cont.
hexagonal key and carefully pull the
temperature handle and shroud off.
3. Push the temperature handle back
onto the cartridge spidle and turn to
increase / decrease the temperature.
• Turn clockwise for a cooler
temperature
• Turn anti-clockwise
for a warmer temperature
Note: This will be the maximum
temperature setting, it is recommended
that the temperature is set no higher
than 43ºC.
4. Once the correct temperature is
achieved, remove the temperature
handle, push the shroud and handle back
on. Tighten the grub screw and re-fit the
indice.
Cooler
Temperature
Handle
Warmer

Advertisement

Table of Contents