General Fault Diagnosis; Cleaning & Maintenance - Bristan Moloko Fitting Instructions & Contents List

Thermostatic surface mounted bar shower valve with fast fit connections
Table of Contents

Advertisement

7.1
If your valve fails to function correctly, the following should be checked:
7.1.1 Check that the hot and cold connections are the correct way around. Hot on the
left, cold on the right when viewed from the front.
7.1.2 Ensure that the hot water temperature is adequate. The recommended minimum
temperature is 60°C.
7.2
If your shower will not turn off:
7.2.1 Check ceramic disc valve is free of debris.
7.3
If your shower has a low flow rate.
7.3.1 Check that the filters (6) are not blocked.
8.1 Cleaning
Your fitting has a high quality finish and should be treated with care to preserve the
visible surfaces.
All surface finishes will wear if not cleaned correctly, the only safe way to clean your
mixer is to wipe with a soft damp cloth. Stains can be removed using washing up liquid.
All bath cleaning powders and liquids will damage the surface of your fitting, even the
non-scratch cleaners.
8.2 Regular Maintenance
We advise that the valve is regularly serviced, particularly in hard water areas. It is also
important to clean the handset regularly in hard water areas to maintain an even
spray/flow of water.
NOTE: ISOLATE THE WATER SUPPLY TO THE SHOWER VALVE.
8.3 Cartridge Removal (See Fig. 1b)
8.3.1 Remove the temperature control handle (10) and shroud (12), by pulling the
handle off the spline adaptor (11).
8.3.2 Unscrew the cartridge (13) anticlockwise.
8.4 Cartridge Maintenance
8.4.1 Place the cartridge in a bowl and carefully add some hot water (just off the boil)
and vinegar to de-scale the cartridge. Leave until the water has cooled.
8.4.2 Then remove the cartridge and rinse with clean water.
For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www.mytub.co.uk

7. General Fault Diagnosis

8. Cleaning & Maintenance
7

Advertisement

Table of Contents
loading

Table of Contents