Real unit ID : 12H
Version
: 1.8
Lines / unit : 8
Block switch : RUN
Timeslot : 000H-00FH (16)
slot info 03
Slot information)
Slot ID : 3
Status : RUNNING
Logical unit ID : BRIU
Dump down message : Disable
Number of Tx errors : 0
Slot started delay : 468.99sec.
Common unit driver information)
Slot ID : 3
Real unit ID : 60H
Version
: 3.3
Lines / unit : 2
Block switch : BLOCK
Timeslot : 040H-043H (4)
BRIU driver information)
To reset the Blade installed in a slot:
slot reset nn
Where nn is the slot number 01 to 10 in hexadecimal.
The Blade is reset, any calls in progress at the Blade are disconnected.
The Blade operates normally after the reset.
The reset has the same operation as removing and re-installing the Blade.
(example – to reset the Blade in slot 3 = slot reset 03 )
Detector
Enter
Function
Detector
List the status of the
DTMF/Tone detectors on
the GCD-CP10 (and
DSPDB if installed).
Firmware loaded onto the Blade
Number of ports on the card (8ESIU)
Block switch set to RUN
Firmware loaded onto the blade
Number of ports on the card (2BRIU)
Block switch set to BLOCK
DIM Output
Number of Channels = 64
CPRU = 32 , DSPDBU = 32
No
Type
01(1401) DTMF
02(0000) NOT USED
03(0000) NOT USED
04(0000) NOT USED
05(0000) NOT USED
:
:
:
:
64(0000) NOT USED
Issue 1.0
Status
Target
ACTIVE
000d
READY
0000
READY
0000
READY
0000
READY
0000
READY
0000