Specifications - PROLiNK PRO800-QS User Manual

Tower online ups
Table of Contents

Advertisement

6. Specifications

MODEL
CAPACITY*
INPUT
Low Line Loss
Voltage Range
Low Line Comeback
High Line Loss
High Line Comeback
Frequency Range
Phase
Power Factor
OUTPUT
Output voltage
AC Voltage Regulation
Frequency Range
(Synchronized Range)
Frequency Range (Batt. Mode)
AC mode
Overload
Battery mode
Current Crest Ratio
Harmonic Distortion
Line
Transfer Time
Inverter
Inverter
EFFICIENCY
AC mode
Battery Mode
BATTERY
Type
Numbers
Recharge Time
Charging Current
Charging Voltage
PHYSICAL
Dimension, DXWXH(mm)
Net Weight (kgs)
IP Rating
ENVIRONMENT
Operation Temperature
Operation Humidity
Operation Altitude**
Acoustic Noise Level
MANAGEMENT
Smart RS-232 or USB
Optional SNMP
* Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC or when UPS is operated in
parallel.
**When using 16 pieces of batteries, the output power factor will be derated to 0.8. If using 18 or 19 pieces of batteries, the output power
factor will be derated to 0.9.
***If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
Product specifications are subject to change without further notice.
6K
≦ 1 % @ 100% Linear Load;
Battery
Bypass
ECO
12 V / 7 Ah
20
7 hours recover to
90% capacity
1 A ± 10% (max.)
592 X 250 X 576
81
Less than 55dB @ 1 Meter
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC
6KL
6000 VA / 6000 W
110 VAC(L-N) ± 3 % at 0-60% Load
176 VAC(L-N) ± 3 % at 60%-100% Load
Low Line Loss Voltage + 10V
300 VAC(L-N) ± 3 %
High Line Loss Voltage - 10V
46Hz ~ 54 Hz @ 50Hz system
56Hz ~ 64 Hz @ 60Hz system
≧ 0.99 at 100% Load
Single phase with ground
208/220/230/240VAC
46Hz ~ 54 Hz @ 50Hz system
56Hz ~ 64 Hz @ 60Hz system
50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
100%~110%: 10min ; 110%~130%: 1min ; >130% : 1sec
100%~110%: 30sec ; 110%~130%: 10sec ; >130% : 1sec
<10 ms (Typical)
93.5% (max.)
92% (max.)
Depending on
applications
16~20**
According to external
battery pack
4 A ± 10% (max.)
(Battery number x 13.65 V) ± 1%
592 X 250 X 576
25
0 ~ 40°C (the battery life will down when > 25°C)
<95 % and non-condensing
Power management from SNMP manager and web browser
25
10K
10000 VA / 10000 W
± 1%
3:1 max
4 % @ 100% Non-linear Load
0 ms
0 ms
12 V / 9 Ah
20
9 hours recover to
90% capacity
1 A ± 10% (max.)
592 X 250 X 576
83
IP20(static)
<1000m
Less than 58dB @ 1 Meter
10KL
Depending on
applications
16~20**
According to external
battery pack
4 A ± 10% (max.)
592 X 250 X 576
27