MODEL NO:
PRO850SFCU
Quick Start Guide
Line Interactive UPS
Version 1.00
(English / Indonesian)
BEFORE GETTING STARTED
This document is designed to aid you to get started with the device. If you experience problems following
these guides or need further information pertaining to the device, please visit our website at
www.prolink2u.com. All specifications are subject to the manufacturer's configuration at the time of
shipping and may change without prior notice, written or otherwise.

Advertisement

Table of Contents
loading

Summary of Contents for PROLiNK PRO850SFCU

  • Page 1 MODEL NO: PRO850SFCU Quick Start Guide Line Interactive UPS Version 1.00 (English / Indonesian) BEFORE GETTING STARTED This document is designed to aid you to get started with the device. If you experience problems following these guides or need further information pertaining to the device, please visit our website at www.prolink2u.com.
  • Page 2: Important Safety Warning

    1. Important Safety Warning CAUTION: To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and humidity range.) To reduce the risk of overheating the UPS, DO NOT cover the UPS' cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces.
  • Page 3: Package Contents

    2. Package Contents MODEL NO: PRO850SFCU Quick Start Guide Line Interactive UPS Version 1.00 (English / Indonesian) BEFORE GETTING STARTED This document is designed to aid you to get started with the device. If you experience problems following these guides or need further information pertaining to the device, please visit our website at www.prolink2u.com.
  • Page 4 3. Overview Legend: LED Indication: • Fault LED : Red lighting • Battery mode LED : Yellow flashing • AC mode LED : Green lighting Power Switch USB port Power AC Input RJ11 Ports: Modem/Fax Protection Backup Outlets Backup Outlets EN 3...
  • Page 5: Installation & Initial Startup

    4. Installation & Initial Startup Note: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Connect to Utility and Charging Plug in the AC input cord to the wall outlet. For the best results, suggest to charge the battery at least 6 hours before initial use.
  • Page 6: Troubleshooting

    5. Software Download & Installation Please follow steps below to download and install monitoring software: Go to the website http://www.power-software-download.com Click ViewPower software icon and then choose your required OS to download the software. Follow the on-screen instructions to install the software. When your computer restarts, the monitoring software will appear as an orange plug icon located in the system tray, near the clock.
  • Page 7: Speci Cations

    7. Speci cations CAPACITY 850VA INPUT Voltage Range 140 - 300VAC ±5% Frequency 50Hz/60Hz (Auto-sensing) Phase Single + GND OUTPUT Voltage Range 230VAC +12% -14% Battery Mode 230VAC ±10% Frequency 50Hz ±1% (Battery Mode) Waveform Simulated Sine Wave (Battery Mode) Sine Wave (AC Mode) Transfer Time Typical 2 - 6ms...
  • Page 8 1. Peringatan Penting Keselamatan PERHATIAN: Untuk mencegah resiko kebakaran atau sengatan listrik, pasang pada daerah yang suhu dan kelembabannya terkontrol (Lihat spesifikasi untuk rentang suhu dan kelembaban yang ditentukan.) Untuk mengurangi resiko overheating dari UPS, JANGAN menutup ventilasi UPS dan menempatkan pada daerah yang terkena sinar matahari langsung atau menempatkan dekat dengan peralatan yang memancarkan panas.
  • Page 9 2. Isi Perangkat MODEL NO: PRO850SFCU Quick Start Guide Line Interactive UPS Version 1.00 (English / Indonesian) BEFORE GETTING STARTED This document is designed to aid you to get started with the device. If you experience problems following these guides or need further information pertaining to the device, please visit our website at www.prolink2u.com.
  • Page 10 3. Ikhtisar Legend: Indikator LED: • LED fault : Menyala Merah • LED modus baterai : Berkedip Kuning • LED modus AC : Menyala Hijau Power Switch Port USB Power AC Input Port RJ11: Modem / Perlindungan Faks Konektor Output Konektor Output ID 3...
  • Page 11 4. Instalasi Dan Sebelum Memulai Catatan: Sebelum melakukan instalasi, mohon unit diperiksa. Pastikan tidak ada yang rusak didalam kemasan. Sambungkan ke Listrik dan Charging Sambungkan kabel power ke sumber listrik. Untuk hasil yang terbaik, disarankan untuk mencharge baterai minimal 6 jam sebelum digunakan.
  • Page 12 5. Software Download & Instalasi Please follow steps below to download and install monitoring software: Pergi ke situs http://www.power-software-download.com Klik ikon perangkat lunak ViewPower dan kemudian memilih OS yang dibutuhkan untuk men-download perangkat lunak. Ikuti petunjuk pada layar untuk menginstal perangkat lunak. Ketika restart komputer anda, software monitoring akan muncul sebagai ikon plug jeruk yang terletak di baki sistem, dekat jam.
  • Page 13 7. Spesi kasi CAPACITY 850VA INPUT Voltage Range 140 - 300VAC ±5% Frequency 50Hz/60Hz (Auto-sensing) Phase Single + GND OUTPUT Voltage Range 230VAC +12% -14% Battery Mode 230VAC ±10% Frequency 50Hz ±1% (Battery Mode) Waveform Simulated Sine Wave (Battery Mode) Sine Wave (AC Mode) Transfer Time Typical 2 - 6ms...
  • Page 14 Register Online For Your Product Warranty @ www.prolink2u.com/register PROLiNK® is a trademark of FIDA INTERNATIONAL (S) PTE LTD and is manufactured under its authority. All other brands, products, services, logos and company names mentioned herein are trademarks of their respective owners. All specifications, designs and contents are subject to changes without prior...