Installing the server cover and bezel

60
Hardware Maintenance Manual: xSeries 340 Model 6RY
c 5 d
Fan 2
To replace a hot-swap fan assembly:
1.
Remove the cover. See "Removing the cover and bezel" on page 47.
Attention: To ensure proper system cooling, do not remove the top cover for
more than 30 minutes during this procedure.
2.
The LED on the failing fan assembly will be lit. Remove the failing fan assembly
from the server by lifting the orange handle on the top of the fan assembly and
and pulling the fan assembly away from the server.
3.
Slide the replacement fan assembly into the server until it clicks into place.
4.
Verify that the FAN LED on the diagnostics panel on the system board is not lit. If
the FAN LED is lit, reseat the fan.
5.
Replace the cover. See "Installing the server cover and bezel".
c 1 d
Cover
c 2 d
Cover-release latch
c 3 d
Flanges
To install the server cover:
1.
Place the cover-release latch in the open (up) position and align the flanges on the
left and right sides of the cover with the slots on the server chassis.
2.
Close the cover-release latch.
To install the bezel:
1.
Align the trim bezel with the front of the server.
2.
Press inward on the top sides of the bezel and press the bezel toward the server
until it clicks into place.
To complete the installation:
If you disconnected any cables from the back of the server, reconnect the cables; then,
plug the power cords into properly grounded electrical outlets.