Replacing a hot-swap fan assembly

c 1 d
Filler panel
c 2 d
Power supply
c 3 d
Handle
c 4 d
AC Power light
c 5 d
DC Power light
To install a power supply:
1.
Remove the filler panel from the empty power supply bay by inserting your
finger into the depression on the filler panel and pulling it away from the server.
Save the filler panel in case you remove the power supply at a later time.
Note: During normal operation, each power-supply bay must have either a
power supply or filler panel installed for proper cooling.
2.
Install the power supply in the bay:
a.
Place the handle on the power supply in the open position (that is,
perpendicular to the power supply) and slide the power supply into the
chassis.
b. Gently close the handle to seat the power supply in the bay.
3.
Plug the power cord for the added power supply into the power cord connector
on the rear of the server.
4.
Plug the power cord into a properly grounded electrical outlet.
5.
Verify that the DC Power light and AC Power light on the power supply are lit,
indicating that the power supply is operating correctly.
Your server comes with three hot-swap fan assemblies. You do not need to turn off the
power to the server to replace a hot-swap fan assembly.
Attention: Replace a fan that has failed within 48 hours to help ensure proper
cooling.
c 1 d
Handle
c 2 d
Fan 3
c 3 d
Fan 1
c 4 d
Fan 2 Error LED
59
Installing options