Table 2. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet controller.
PCNTNW-NW-054 The adapter did not respond to the initialization command.
PCNTNW-NW-058 The adapter did not respond to the initialization command.
PCNTNW-NW-066 The cable might be disconnected from the adapter.
PCNTNW-NW-071 The matching virtual adapter could not be found.
PCNTNW-NW-072 A resource tag is unavailable.
PCNTNW-NW-073 Unable to allocate memory
PCNTNW-NW-074 The hardware interrupt cannot be set.
20
Hardware Maintenance Manual: xSeries 340 Model 6RY
Explanation: The adapter did not respond when the driver tried to initialize
it.
Action: Verify that the Ethernet controller is enabled. If the Ethernet
controller is enabled, go to "Starting the diagnostic programs" on page 14 to
run the diagnostic programs.
Explanation: The interrupt request (IRQ) setting might not be valid or the
EEPROM information might be incorrect.
sure the IRQ settings are correct in the Configuration/Setup Utility program.
for information on setting the interrupt requests. If the IRQ settings are
correct, go to "Starting the diagnostic programs" on page 14 to run the
diagnostic programs.
Explanation: The cable might be disconnected from the server Ethernet port.
Action: Verify that a cable is connected to the Ethernet port.
Explanation: You tried to load another instance of the driver with a different
I/O address. This new adapter could not be found.
Action: Verify that you installed an IBM Netfinity 10/100 Fault Tolerant
Adapter and make sure that the adapter is seated correctly. If the adapter is
seated correctly, go to "Starting the diagnostic programs" on page 14 to run
the diagnostic programs..
Explanation: The driver tried to allocate some resources that were not
available.
Action: Add more memory, or free some memory resources in the server.
Then, restart the server.
Explanation: The driver failed to allocate the memory needed for normal
operation.
Action: Add more memory, or free some memory resources in the server.
Then, restart the server.
Explanation: An attempt was made to initialize a given hardware interrupt.
The attempt was not successful.
Ethernet controller is enabled. If the Ethernet controller is enabled, go to
"Starting the diagnostic programs" on page 14 to run the diagnostic
programs.
If you have an Ethernet adapter installed, make sure that the adapter does
not share an IRQ with any other device.