Table 5. UNIX LLI driver messages for the Ethernet controller.
pnt0-13
add_intr_handler failed! Interrupts already enabled.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action: Modify your hardware settings.
pnt0-14
Cannot locate hardware.
Explanation: The SunSoft Solaris driver cannot find any Ethernet controller. Action: Verify that
the Ethernet controller is enabled. If the Ethernet controller is enabled, run the diagnostic
programs.
No more devices to open.
pnt0-15
Explanation: The SunSoft Solaris driver cannot find any more Ethernet controllers.
Action: Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or
replace the Ethernet adapter that fails to respond. If the problem persists, run the diagnostic
programs.
pnt0-17
Device fault...Reset initiated!
Explanation: The SunSoft Solaris driver has been reset due to a device fault. Action: Verify that
additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or replace the Ethernet
adapter that fails to respond. If the problem persists, run the diagnostic programs.
pnt0-19
IRQ found for PCnet hardware does not match space.c (or pnt.conf)!
Explanation: This is a warning message referring to the interrupt request (IRQ) that the SunSoft
Solaris driver found in the system.
Action: Ignore this message if you are sure that this is what you want to do. Otherwise, run the
NETCONFIG program to match the hardware settings
pnt0-20
add_intr_handler failed! Unknown interrupt type.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
add_intr_handler failed! Out of range interrupt number.
pnt0-21
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
pnt0-22
add_intr_handler failed! Out of range IPL.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action: Modify your hardware settings. Run the NETCONFIG program to search for another
Ethernet controller.
pnt0-23
add_intr_handler failed! Vector already occupied.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action: Modify your hardware settings.
Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.