IBM x 340 Series Hardware Maintenance Manual page 132

Table of Contents

Advertisement

Error Code/Symptom
1800
(No more hardware interrupt
available for PCI adapter)
1962
(Drive does not contain a valid
boot sector)
2400
(Video controller test failure)
2462
(Video memory configuration
error)
5962
(IDE CD-ROM configuration
error)
8603
(Pointing Device Error)
00019501 (Processor 1 is not functioning -
check VRM and processor LEDs)
00019502 (Processor 2 is not functioning -
check VRM and processor LEDs)
00019701
(Processor 1 failed )
00019702 (Processor 2 failed )
00180100
(No room for PCI option
ROM)
00180200
(No more I/O space
available for PCI adapter)
00180300
(No more memory (above
1MB for PCI adapter)
124
Hardware Maintenance Manual: xSeries 340 Model 6RY
1.
Run Configuration/Setup
2.
Failing Adapter
3.
System Board
1.
Verify a bootable operating system is installed.
2.
Run Diagnostics
3.
Hard Disk Drive
4.
SCSI Backplane
5.
Cable
6.
System Board
1.
Video Adapter (if installed)
2.
System Board
1.
Video Adapter (if installed)
2.
System Board
1.
Run Configuration/Setup
2.
CD-ROM Drive
3.
CD-ROM Power Cable
4.
IDE Cable
5.
System Board
6.
Battery
1.
Pointing Device
2.
System Board
1.
VRM 1, VRM 2
2.
Processor 1
3.
System Board
1.
VRM 2
2.
Processor 2
1.
Processor 1
2.
System Board
1.
Processor 2
2.
System Board
1.
Run Configuration/Setup
2.
Failing Adapter
3.
System Board
1.
Run Configuration/Setup
2.
Failing Adapter
3.
System Board
1.
Run Configuration/Setup
2.
Failing Adapter
3.
System Board
FRU/Action

Advertisement

Table of Contents
loading

This manual is also suitable for:

6ry

Table of Contents