IBM x 340 Series Hardware Maintenance Manual page 125

Table of Contents

Advertisement

Error Code/Symptom
089-XXX-002
Optional Microprocessor test)
165-XXX-000
(Failed Service Processor
test)
180-XXX-000 (Diagnostics LED failure)
180-XXX-001
(Failed information LED
panel test)
180-XXX-002
(Failed Diagnostics LED
Panel test)
180-XXX-003
(Failed System Board LED
test)
180-XXX-004
(Failed System Board
LED test)
180-XXX-005
(Failed SCSI
Backplane LED test)
180-XXX-006 (Memory Board LED test)
(Failed Memory test,
201-XXX-0NN
see "Memory Settings" on page 33)
201-XXX-999 (Multiple DIMM failure, see
error text)
202-XXX-001
(Failed System Cache
test)
202-XXX-002
(Failed System Cache test) 1.
206-XXX-000
(Failed Diskette Drive test) 1.
215-XXX-000
(Failed IDE CD-ROM
test)
(Failed
1.
VRM 2 for Optional Microprocessor 2
2.
Optional Microprocessor 2
1.
System Board. Before replacing the System Board, ensure that
System Board jumper J45 is not installed (the default) when the error
occurs.
2.
Power Backplane
3.
Hot-Swap Drive Backplane
1.
Run Diagnostic LED test for the failing LED.
1.
Information LED Panel
2.
Power Switch
3.
Assembly
1.
Diagnostics LED Panel
2.
Power Switch
3.
Assembly
1.
System Board
1.
System Board
1.
SCSI Backplane
2.
SCSI Backplane Cable
3.
System Board
1.
Memory Board
2.
System Board
1.
DIMM Location slots 1-4 where NN = DIMM location.
Note:
2.
System Board
1.
See error text for failing DIMMs
2.
System Board
1.
VRM 1
2.
Microprocessor 1
VRM 2
2.
Microprocessor 2
Cable
2.
Diskette Drive
3.
System Board
1.
CD-ROM Drive Cables
2.
CD-ROM Drive
3.
System Board
FRU/Action
NN=1=DIMM 2 =2=DIMM 1 =3=DIMM 4 =4=DIMM 3
117
Symptom-to-FRU index

Advertisement

Table of Contents
loading

This manual is also suitable for:

6ry

Table of Contents