Texas Instruments SimpleLink CC2651R3SIPA Manual page 21

Multiprotocol 2.4 ghz wireless system-in-package module with integrated antenna & 352-kb memory
Table of Contents

Advertisement

www.ti.com
8.15.4 Synchronous Serial Interface (SSI) Characteristics
8.15.4.1 Synchronous Serial Interface (SSI) Characteristics
over operating free-air temperature range (unless otherwise noted)
PARAMETER
NO.
S1
t
clk_per
(1)
S2
t
clk_high
(1)
S3
t
clk_low
(1)
Refer to SSI timing diagrams Figure 8-1, Figure 8-2, and Figure 8-3.
(2)
When using the TI-provided Power driver, the SSI system clock is always 48 MHz.
SSIClk
SSIFss
SSITx
SSIRx
Figure 8-1. SSI Timing for TI Frame Format (FRF = 01), Single Transfer Timing Measurement
S2
SSIClk
S3
SSIFss
SSITx
MSB
SSIRx
Figure 8-2. SSI Timing for MICROWIRE Frame Format (FRF = 10), Single Transfer
Copyright © 2023 Texas Instruments Incorporated
PARAMETER
SSIClk cycle time
SSIClk high time
SSIClk low time
S1
S2
S3
MSB
S1
LSB
8-bit control
Product Folder Links:
SWRS278B – FEBRUARY 2022 – REVISED AUGUST 2023
MIN
12
LSB
4 to 16 bits
0
MSB
4 to 16 bits output data
CC2651R3SIPA
CC2651R3SIPA
TYP
MAX
UNIT
65024
System Clocks
0.5
t
clk_per
0.5
t
clk_per
LSB
Submit Document Feedback