Convection Box Installation; Method 1 - Front Fixing To Fireplace Surround; Method 2 - Cable Retention And Floor Fixing - Vision Ezi-Slide V150 B Installation & User's Instructions

Control gas fire
Table of Contents

Advertisement

INSTALLER GUIDE
INSTALLER GUIDE

9. CONVECTION BOX INSTALLATION

9. CONVECTION BOX INSTALLATION

9.1 Method 1 - Front fixing to fireplace surround.

1. Make sure that the fireplace front surround area is sound enough to take the fibre
plugs and woodscrews. If necessary, make
sound with suitable cement.
2. Place the convection box centrally in the
fireplace in the position in which it is to be
permanently installed. If a concealed
connection is being used, insert the
convection box into the fireplace feeding the
supply pipe through the pierced hole in the
rear grommet.
3. Mark the fireplace front surround through
the four fixing holes in the side flanges of the
convection box (See figure 16).
4. Remove the convection box. Drill four
holes in the fireplace front surround at the
Figure 16. Front fixing
marked positions using a suitably
sized masonry drill for the wall
plugs supplied.
5. Insert a fibre plug into each
hole.
6. Place the convection box back
in position in the fireplace.
7. Fit a woodscrew through each
hole in the convection box flanges
and tighten to seal the box to the
fireplace surround.
9.2 Method 2 - Cable retention
and floor fixing.
1. Make sure that the relevant
areas at the fireplace back or
floor are sound enough to take
the eyebolts and screws. If these
areas have deteriorated due to
prolonged use they should be
made sound with suitable cement.
2. Drill four holes in the rear wall
of the fireplace for the eyebolt
plugs. The holes should be drilled
Figure 17. Eyebolt positions
within the range of positions
22

Advertisement

Table of Contents
loading

Table of Contents