To Remove The Fascia; To Replace The Control Slide Unit; To Replace The Control Slide Button; To Remove The Burner Unit - Vision Ezi-Slide V150 B Installation & User's Instructions

Control gas fire
Table of Contents

Advertisement

INSTALLER GUIDE

16.5 To replace the control slide unit.

1. Remove the fascia (See section 16.4).
2. Remove the screw and disconnect the control
linkage (See figure 32)
3. Detach the slide unit by removing two screws
securing the slide mechanism to the right hand
flange of the fire.
4. Replace in the reverse order.

16.6 To replace the control slide button.

1. Remove the fascia (See section 16.4).
2. Remove the control slide unit (See section 16.5)
3. Detach the slide button by removing two screws.
4. Replace in the reverse order.

16.7 To remove the burner unit.

1. Remove the fire front and fascia - See section 16.4.
2. Remove the loose ceramic fuel effect pieces, the front ceramic fuel effect and the
base ceramic fuel effect.
3. Close the isolating valve in the inlet 'T' connector. Support the inlet 'T' connector to
avoid straining the pipework and disconnect the appliance from the 'T' connector.
4. Detach the burner unit from the convection box by removing two screws (See
figure 34).
5. Replace in the reverse order.
INSTALLER GUIDE
Figure 34. Burner attachment points
Figure 32. Control linkage
disconnection