OWNER GUIDE

SAFETY

DON'T SMOKE.
-
EXTINGUISH ALL NAKED FLAMES.
-
DON'T TURN ELECTRICAL SWITCHES ON OR OFF.
-
TURN OFF THE GAS SUPPLY AT THE METER OR TANK AS APPROPRIATE.
-
OPEN DOORS AND WINDOWS TO GET RID OF THE GAS.
-
IMMEDIATELY CALL THE GAS EMERGENCY SERVICE FROM A
-
NEIGHBOURS PHONE - SEE YOUR LOCAL TELEPHONE DIRECTORY.
Do have the fire installed by a competent person. In the United Kingdom, installation
must be in accordance with the latest edition of the Gas Safety (installation & use)
Regulations. In the Republic of Ireland, installation must be in accordance with all
national and local regulations in force.
Do have the chimney swept prior to installation if it was previously used for solid fuel.
Do have the fire installed in accordance with the installation instructions.
Do allow a minimum clearance of 760 mm from the top of the base of the convector
box to the underside of any shelf whether it is made from combustible or non-
combustible materials. For a shelf made from wood or other combustible materials
deeper than 150mm add 12.5mm to the clearance for every 25mm of additional shelf
depth (See figure 1). Please bear this in mind if ever you add a shelf.
Figure 1. Combustible shelf clearances
40
OWNER GUIDE
SAFETY
IF YOU SMELL GAS