Adjustment procedure
Select a colour temperature to be set
1
in [Colour temperature].
Set the front side of the sensor
2
toward the panel within the square
displayed in the center of the
screen.
Sensor module
Select [Start adjustment] and press
3
<ENTER>.
The adjustment starts.
When [Adjust OK] is displayed, the
4
adjustment is complete.
When [Adjust failed] is displayed, perform
adjustment again.
Start adjustment
Reset
Adjust OK
[2 screens colour matching adjust]
Matches the colours of 2 displays using the color
sensor.
2 screens colour matching adjust
Colour temperature
Reference set measurement start
Adjust set adjust start
[Colour temperature]:
Displays the colour temperature setting of the
reference display.
[Reference set measurement start]:
Starts measurement by selecting this item after the
sensor is set on the reference display.
[Adjust set adjust start]:
Starts adjustment by selecting this item after the
sensor is set on the display to be adjusted.
Note
Connect between the 2 displays using an RS-232C
cross cable (female-female).
Check that [Control settings] is set as shown below
on the 2 displays.
[Serial control] is set to [SERIAL IN].
[Serial response (Normal)] is set to [On].
When setting the sensor module to the panel, do not
push it too strong.
When attaching the sensor module to the display
again, use a spare double-sided tape, etc.
Before adjustment, energize the unit for at least 1
hour in picture signal displayed state.
Use the sensor module of the display to be adjusted.
Menu operation is not available when on the
reference display [Picture] - [Colour temperature] is
set to [Native], [User1] or [User2].
Operation is not available when [Picture] - [Picture
mode] of the display to be adjusted is set to [DICOM].
10700K
English
95