Initial operation
4
EN
4
Initial operation
The CellClutch tool and the tightening sequence are configured with the CLPC100 software.
4.1
Configuring the access point
4.1.1
mPro200GC-AP
In the factory setting, the IP address and the subnet mask of the controller are specified with a default
value (Ethernet 1):
Parameter
IP address
Subnet mask
Note
IP address conflict
The 200 Series controllers have a factory default IP address of 192.168.100.200. If multiple controllers
are connected to the same network without changing the original IP address, an IP conflict occurs.
► Assign a new, unique IP address to each controller.
Configuring the access point
1.
Connect laptop/PC directly to the controller via an Ethernet cable.
2.
Start mProRemote Professional on the Laptop/PC.
3.
Enter the IP address 192.168.100.200 in the Remote Control tab in the Target input field.
4.
Press Remote (TCP/IP).
5.
Select Navigator > Utility > System Settings > Cordless Tools.
6.
Open the WLAN AP Configuration.
7.
Carry out the desired settings for the configuration of the access point.
8.
Press <Apply> to save the changes.
This tab is only displayed for the series mPro200GC(-AP) controller.
Fig. 4-1: WLAN AP Configuration tab
10
Default value
192.168.100.200
255.255.255.0
A connection to the controller is established.
The user interface of the controller opens on the laptop/PC.
P2545KA | 2022-12 | REV C
Apex Tool Group
Need help?