Installing Sitrans Ms200 On A Gear; Installing Sitrans Ms200 On Rotating Or Vibrating Equipment; Disassembly Sitrans Ms200 - Siemens SITRANS SCM IQ Operating Instructions Manual

Smart condition monitoring with iiot sensors
Hide thumbs Also See for SITRANS SCM IQ:
Table of Contents

Advertisement

Installing/mounting
5.3 Disassembly SITRANS MS200
5.2.4

Installing SITRANS MS200 on a gear

Mount SITRANS MS200 directly on the gear. The most suitable place is at the middle of the gear
in the horizontal position.
NOTICE
Maximum specified ambient temperature
The maximum specified ambient temperature must not be exceeded by the gear. See Technical
specifications SITRANS MS200 (Page 87).
Note
SITRANS MS200 must not get in contact with gear oil or gear oil vapors.
5.2.5

Installing SITRANS MS200 on rotating or vibrating equipment

Any rotating or vibrating equipment can be supervised with SITRANS MS200. Mount SITRANS
MS200 as close as possible to vibrating components.
NOTICE
Maximum specified ambient temperature
The maximum specified ambient temperature must not be exceeded by the rotating or
vibrating equipment. See Technical specifications SITRANS MS200 (Page 87).
5.3

Disassembly SITRANS MS200

Incorrect disassembly
In order to disassemble correctly, observe the following:
• Before starting work, make sure that you have switched off all physical variables such as
• Make sure that no environmentally hazardous media are released.
• Secure the remaining connections so that no damage can result if the process is started
40
WARNING
pressure, temperature, electricity etc. or that they have a harmless value.
unintentionally.