Installing/mounting Monitoring with IIoT Sensors Connecting SITRANS CC220 Operating Instructions Commissioning Operating Service and maintenance Diagnostics and troubleshooting Technical specifications Dimension drawings Product documentation and support 7MP2200-2CB05-2AA1 (SITRANS CC220) 7MP2210-2AB21-2AB1 (SITRANS MS200) Insights Hub application SITRANS SCM IQ 07/2023 A5E50573389-AD...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure...
This product includes third-party software. Siemens AG only provides a warranty for updates/ patches of the third-party software, if these have been distributed as part of a Siemens software update service contract or officially released by Siemens AG. Otherwise, updates/patches are undertaken at your own risk.
The content reflects the technical status at the time of publishing. Siemens reserves the right to make technical changes in the course of further development.
RoHS and electronic equipment The applicable directives can be found in the EU declaration of conformity of the specific device. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Note Operation under special ambient conditions We highly recommend that you contact your Siemens representative or our application department before you operate the device under special ambient conditions as can be encountered in nuclear power plants or when the device is used for research and development purposes.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
• Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and protect from direct sunlight, moisture and condensation. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
3.5.2 Data protection Siemens observes the data protection guidelines, especially the requirements regarding data minimization (privacy by design). This means the following for this product: The product does not process or save any personal information, but only technical functional data (For example time stamps).
• The device can be identified by collecting MAC/UID information from the system. • Note that the debug interface X14 on the motherboard is used for development purposes. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
When you touch electrostatic sensitive components, you can destroy them through voltages that are far below the human perception threshold. If you work with components that can be destroyed by electrostatic discharge, observe the ESD Guideline. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
SITRANS MS200 is delivered with an LTC (Lithium Thionyl Chloride) battery pack offered by Siemens. • Use SITRANS MS200 with the delivered battery pack only. See also Ordering of spare parts (Page 78) SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
SITRANS CC220. SITRANS CC220 transmits the information encrypted to Insights Hub. In the SITRANS SCM IQ application, the status data of the monitored plant components or systems can be displayed graphically. For more information, watch this video (https://www.youtube.com/watch?v=-z4IaupJLjo). SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Ring buffer means: as soon as the 8th day begins, the data of the 1st day are overwritten. • If the connection between the sensor and the SITRANS CC220 gateway is lost, the data is not cached on the sensor. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
See chapter Resetting or disconnecting SI‐ TRANS CC220 from SITRANS SCM IQ (Offboard‐ ing) (Page 62) ② ⑦ USB 1-X60 port Shield cover ③ ⑧ Power supply connector Top housing SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
⑩ LED display. Bluetooth antenna See chapter Meaning of the LED states on SITRANS CC220 (Page 83) SITRANS MS200 design ① ③ Reset button ② ④ Battery connector SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
• Observe the relevant DIN/VDE requirements or the applicable country-specific regulations. • Install the bluetooth antenna outside the cabinet. • To install the mounting clamps and brackets, Siemens recommends you use 0.6 Nm tightening torque. Before mounting the device You have all needed anchors and screws available.
Page 26
5. Bring the bluetooth antenna in a vertical position. Mounting example in a cabinet See technical details of the bluetooth antenna extension in chapter Technical specifications SITRANS CC220 (Page 85). SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Ensure that the following clearances measurements to another component or to a wall of a housing are complied with: • Below the device: ≥ 50 mm • Above the device: ≥ 50 mm SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Requirement • The DIN rail is installed at the installation site (35 mm standard profile). • Mounting bracket and mounting clamps • Two screws • T8 screwdriver SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 29
3. Lay the brackets on the rear of the device. Align the bracket edge with the device edge. 4. Fasten the brackets with the sup‐ plied screws. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
1. Push down the device until it is released by the rail clamp. 2. Swing the device out of the standard profile rail. 3. Lift the device up and off. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
2. Fasten the brackets with supplied screws. 3. Mark the bore holes, drill the required holes in the wall and fasten the device to the wall using two screws. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
2. Fasten the brackets with supplied screws. 3. Mark the bore holes, drill the required holes in the wall and fasten the device to the wall using two screws. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Before replacing the backup battery • The device is disconnected from the power supply. • You have removed the bluetooth antenna. • You have the replacement battery (Page 36) available. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 34
Remove the top housing of the enclosure. Remove the marked screws on the motherboard. Remove the motherboard. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 35
Plug in the battery cable on the motherboard. Then install the motherboard again and install the top housing (Page 36). SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
2. Insert the two plastic clips of top housing into the clip holes on heatsink. 3. Press the top housing to fix the clips. Then install power plug and screws for COM interface. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Note Material compatibility Siemens can provide you with support concerning selection of parts wetted by process media. However, you are responsible for the selection of parts. Siemens accepts no liability for faults or failures resulting from incompatible materials. CAUTION Hot surfaces resulting from hot process media Risk of burns resulting from surface temperatures above 65 °C (149 °F).
• directly mount SITRANS MS200 to an existing stud bolt • use a short threaded bolt to mount SITRANS MS200 to a threaded hole • use a clamp shell to mount SITRANS MS200 to a pipe SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Note Mount SITRANS MS200 so that the lid can be easily removed in the mounted state for a later battery pack replacement (Page 72). For more information, watch this video: SITRANS SCM IQ: How to mount the Multisensor (https://www.youtube.com/watch?v=kHCWsAgltqE) See also Dimension drawings SITRANS MS200 (Page 92)
• Make sure that no environmentally hazardous media are released. • Secure the remaining connections so that no damage can result if the process is started unintentionally. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
(MOV) UMOV = U-rated x 1.2 (BLITZDUCTOR BVT AVD 24 (918 422) or compatible). Note The connection line shall meet the requirements of IEC 60332-1-2 and IEC 60332-1-3 or alternative the requirements of IEC/TS 60695-11-21. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
The functional grounding also improves the discharge of interference generated by external power cables, signal cables or cables for I/O modules to ground. The connection for the functional grounding is labeled with the following symbol: SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 43
M4 thread with the torque of 1 Nm (see part labeled). 3. Connect the functional grounding to the protective conductor connection of the cabinet or the plant in which the device is installed. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
⇒ After onboarding (Page 52): – If there is an active internet connection USER 2 LED is lighting green. – If there is no internet connection USER 2 LED is blinking fast orange. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
• Before commissioning take the effect on other devices in the system into account. Starting SITRANS SCM IQ in Insights Hub Required user roles • Insights Hub user role: TenantAdmin or assetmanager.admin SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
8. Click "Save". ⇒ SITRANS SCM IQ or SITRANS Anomaly IQ is visible on Insights Hub Launchpad. Administrating the network for SITRANS CC220 Required user role Network administrator of your site. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
• Prevent grease or other contaminants from touching PCB, as this could reduce battery life. • Avoid direct skin contact with PCB. Introduction For more information, watch this video (https://www.youtube.com/watch?v=kHCWsAgltqE). SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 48
Procedure 1. Put on a clean pair of gloves. ② ① 2. Unscrew the sensor lid: Hold with an open-ended wrench at and turn the lid counterclockwise. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 49
3. Connect the battery connector to the PCB. ③ ⇒ The LED placed on the PCB lights up for one second after the boot process is completed (up to 10 seconds). SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Asset in Insights Hub refer to Insights Hub documentation area (https://documentation.mindsphere.io/MindSphere/apps/asset-manager/create-an- asset.html#create-an-asset). For more information, watch this video: SITRANS SCM IQ: How to onboard the Gateway and Multisensor (https://www.youtube.com/watch?v=AJLLbYmtN2A&t=36s). SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors...
Repeat this procedure for each SITRANS MS200. Enabling existing Insights Hub Assets for SITRANS SCM IQ To enable your existing Insights Hub Assets for SITRANS SCM IQ you add the Aspect generic_scmiq_anomalydetection to your Insights Hub Assets. For more information, watch this video: SITRANS SCM IQ: How to add Machine Data to SITRANS SCM IQ (https://www.youtube.com/watch?v=AG31J1v3gB8&t).
Page 53
⇒ The onboarding key is generated and available in the download folder set in your browser settings. ⇒ LAN interface X1P1LAN of SITRANS CC220 will be configured according to the connection settings. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
The following procedure describes how to connect SITRANS MS200 sensors with SITRANS SCM IQ. Each SITRANS MS200 needs to be assigned to a SITRANS CC220 gateway and mapped to a specific Asset in the Asset structure in Insights Hub (see Integrating SITRANS MS200 as Insights Hub Asset (Page 50)).
Configured users will receive notifications when an anomaly is detected by the application. To configure the anomaly detection model please refer to Training anomaly detection models (Page 57). For more information, watch this video (https://www.youtube.com/watch? v=AJLLbYmtN2A&t=352s). SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 56
6. Enter the details for the user group and select the users that shall be assigned to this group. 7. Select the type of notification (SMS and/or e-mail). 8. For e-mail notifications additional options can be configured. 9. Click "Save". SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
After the trained model is available, you can start the model for continuous anomaly detection. For more information, watch this video: SITRANS SCM IQ: How to add Machine Data to SITRANS SCM IQ (https://youtu.be/AG31J1v3gB8).
Page 58
6. For an asset type "Machine Data Assets" select the Aspect Variables which will be considered for the anomaly detection model. 7. Select the data which will be considered for the anomaly detection model. Multiple time ranges can be selected. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 59
After deploying an anomaly detection model, anomalies are automatically detected when they occur. You can manage the anomalies in the SITRANS Anomaly IQ application provided in your Insights Hub Tenant. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
8.2 Managing anomalies in SITRANS Anomaly IQ Managing anomalies in SITRANS Anomaly IQ If you deployed an anomaly detection model in SITRANS SCM IQ, you find all detected anomalies in the SITRANS Anomaly IQ application. No further configuration is necessary to use SITRANS Anomaly IQ. You can enter information relevant to solve anomalies. This information is available as a documentation for later use or to share the information with other users that have access to your application.
If you disconnect a SITRANS CC220, observe the following consequences: • connection to SITRANS CC220 gets lost • SITRANS CC220 is removed from device list in SITRANS SCM IQ • SITRANS MS200 paired with this SITRANS CC220 are removed from sensor list • timeseries data on assets will be kept in Insights Hub but not updated anymore If you disconnect a SITRANS MS200, observe the following consequences:...
Operating 8.5 Resetting SITRANS MS200 Resetting or disconnecting SITRANS CC220 from SITRANS SCM IQ (Offboarding) • Press the USER button on the SITRANS CC220 for at least 5 seconds. ⇒ USER LEDs blinking red. ⇒ USER 1 LED is blinking red and USER 2 LED is off.
– SITRANS CC220 (https://support.industry.siemens.com/cs/de/en/ps/28809/man) – SITRANS MS200 (https://support.industry.siemens.com/cs/de/en/ps/28810/man) • in SITRANS SCM IQ in the "OS Bar" • on the root of the SD card delivered with the SITRANS CC220 gateway SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors...
Page 64
Operating 8.6 Accessing the OSS Readme and source code SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
WARNING Impermissible repair and maintenance of the device • Repair and maintenance must be carried out by Siemens authorized personnel only. CAUTION Hazardous voltage at open device Risk of electric shock when the enclosure is opened or enclosure parts are removed.
We are not liable for functional limitations caused by using third-party devices or components. 9.1.2 Sending the log files to technical support Introduction For diagnostics you can export the SITRANS CC220 log files to a USB stick. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 67
7. If no LED is blinking anymore, remove the USB stick from SITRANS CC220. 8. Send the log files to the Technical support (Page 94). 9. Before you establish a connection of SITRANS CC220 to SITRANS SCM IQ again (Onboarding), remove the "ConBox_Commands.json" file from the USB stick.
Before replacing the backup battery • The device is disconnected from the power supply. • You have removed the bluetooth antenna. • You have the replacement battery available. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 69
Remove the top housing of the enclosure. Remove the marked screws on the motherboard. Remove the motherboard. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
2. Replace defective SITRANS CC220 with new SITRANS CC220. 3. Disconnect defective SITRANS CC220 in SITRANS SCM IQ. 4. Connect new SITRANS CC220. 5. Reconnect old SITRANS MS200 with SITRANS SCM IQ to the same Insights Hub asset. 6. Reset SITRANS MS200. Resetting SITRANS MS200 (Page 62) 9.1.5...
Penetration of moisture into the device Damage to device. • Make sure when carrying out cleaning and maintenance work that no moisture penetrates the inside of the device. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
(max. 5° angle difference). Note Battery temperature for replacement The temperature difference between the new battery and the battery to be replaced should not exceed +/-5 °C. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 73
Make sure you take precautionary measures even when you open the device, for example, when opening device doors, device covers or the housing cover. For more information, refer to the ESD Guideline. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 74
Service and maintenance 9.2 Maintenance and repair work for SITRANS MS200 ③ 3. Disconnect the battery connector ④ 4. Unwrap the wires ⑤ 5. Disengage the snaps SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 75
⑦ 7. Take off the battery holder cap 8. Lift and exchange the battery pack with a Siemens specified battery pack (see Battery pack specification (Page 20)). Ensure that the positive terminal of the battery pack points upwards. 9. Wrap the cable in its original position using the dedicated snaps of the battery holder.
5. Connect new SITRANS MS200 with SITRANS SCM IQ and assign sensor to existing Insights Hub asset. For detailed description see Commissioning SITRANS MS200 with SITRANS SCM IQ (Page 54). 6. Train new anomaly detection model based on new SITRANS MS200 data. Repositioning SITRANS MS200 on the same machine Note In this scenario SITRANS CC220 and Insights Hub asset remain the same. ...
Page 77
1. Stop anomaly detection models of the respective SITRANS MS200. 2. Reposition SITRANS MS200. 3. Make sure SITRANS MS200 is powered up. 4. Change assignment to Insights Hub asset of SITRANS MS200 in SITRANS SCM IQ by clicking on "Device configuration > > Configure sensor".
Service and maintenance 9.3 Ordering of spare parts 1. Stop anomaly detection models of the respective SITRANS MS200. 2. Change assignment to Insights Hub asset of SITRANS MS200 in SITRANS SCM IQ by clicking on "Device configuration > > Configure sensor". 3. Delete machine learning models based on old data from asset (if existing) by clicking on "Sensor data modelling"...
5. Select a spare part and add it to your watch list. The watch list opens. 6. Click "Add to cart of Industry Mall". The Siemens Industry Mall opens and you can order your spare part. Cleaning Cleaning the enclosure •...
To return a product to Siemens, see Returns to Siemens (https:// support.industry.siemens.com/cs/ww/en/sc/3098). Contact your Siemens representative to clarify if a product is repairable, and how to return it. They can also help with quick repair processing, a repair cost estimate, or a repair report/ cause of failure report.
Note Special disposal required The device includes components that require special disposal. • Dispose of the device properly and environmentally through a local waste disposal contractor. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 82
Service and maintenance 9.7 Disposal SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
USER 1 LED is blinking slow orange FW update failed. Press reset button. USER 2 LED is blinking slow red See also Technical specifications SITRANS CC220 (Page 85) SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
10.2 Troubleshooting Symptom Cause of error Remedy SITRANS SCM IQ is not working anymore. SitransMS Connector has been deleted 1. Open SITRANS SCM IQ. from Insights Hub Agent. ⇒ An installation request for the missing Insights Hub Agent Si‐ transMS Connector opens.
1 GB LAN port P1 - X1 LAN - P1, RJ45 Table 11-1 USB stick specifications USB stick specifications Type USB 2.0 Type A Supported formatting FAT32 SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Page 86
Power Supply DC 12 to 24 V Power consumption max. 15 W Wireless communication Bluetooth® (standard) Wireless protocol Bluetooth® low energy (BLE) 5.1 Frequency range 2 400 ... 2 480 MHz Max. transmit power +5.5 dBm SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
Storage temperature -40 ... 85 °C Ambient temperature (operation) -30 ... 80 °C Altitude Operation: -1000 ... 2000 m (pressure 795 ... 1080 hPa) Rating IP68 (2 m, 24 h) Temperature measurement Temperature range -30 ... +80 °C Resolution 0.01 °C Repeatability ±0.15 °C SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
1. Scan the QR code on your device with a mobile device. 2. Click "PIA Portal". To display factory certificates, if available, log in to the PIA Life Cycle Portal using your login or register. SITRANS SCM IQ: Smart Condition Monitoring with IIoT Sensors Operating Instructions, 07/2023, A5E50573389-AD...
(http:// www.siemens.com/automation/csi/service). Service & support on the Internet In addition to our technical support, Siemens offers comprehensive online services at service & support (http://www.siemens.com/automation/serviceandsupport). Contact If you have further questions about the device, contact your local Siemens representative at Personal Contact (http://www.automation.siemens.com/partner).