6.23

EMI Filter Removal

6.23.1 Remove the lower tub as per instructions in 6.11.
6.23.2 The EMI filter is located at the rear left hand side of the chassis base.
6.23.3 Remove the screw in the rear access panel of the chassis.
6.23.4 Raise the insulating cover to expose the EMI filter.
6.23.5 The EMI filter can now be replaced or serviced.
6.23.6 Refit in reverse manner.
6.24

Tub Microswitch Removal

Note: Located on the rear of the left slide runner and connected in series with the
exhaust valve, this component can be serviced by two methods.
6.24.1 Method 1:
Remove the slide runner as per instructions in 6.15.
6.24.2 Method 2:
Remove lower kickstrip as per instructions in 6.7.
6.24.3 Remove the clip pegs from the slide runners.
6.24.4 Slide the DishDrawer from the cavity to allow servicing from the rear.
6.24.5 Remove the screw securing the rear service panel.
6.24.6 Fit a screwdriver through the hole in the rear service panel and lift or tap the shaft
of the screwdriver up so as to disengage the panel from its retainers.
6.24.7 The service procedures from now on are the same for both methods.
6.24.8 Disconnect the wiring to the microswitch.
6.24.9 Release the microswitch from the retaining clips on latch retaining mechanism on
the drawer slide.
6.24.10 Refit in reverse manner.