Tub Removal; Locking Ring, Element Plate And Motor Assembly Removal - Fisher & Paykel DS6021 Service Manual

Table of Contents

Advertisement

6.11

Tub Removal

6.11.1 Remove the drawer front as per instructions in 6.1.
6.11.2 Remove the wiring cover as per instructions in 6.8.
6.11.3 Disconnect the fill hose from the dispenser (water may drip)
6.11.4 Disconnect the mains harness and chassis harness connectors from the electronic
controller.
6.11.5 Unclip the drain hose cuff from the motor assembly.
6.11.6 From the under side of the tub now unclip the drain hose, fill hose and the wiring
looms which go to the link assembly. Disconnect the earth wire off the element
plate.
6.11.7 The link assembly can now be unhooked from the rear of the tub by pressing the
spigots back through the tub connection point.
6.11.8 The tub may now be lifted at the front and slipped forward off the slide runners.
6.11.9 Refit in reverse manner.
6.12

Locking Ring, Element Plate and Motor Assembly Removal

6.12.1 Remove the drawer front, tub, filter plate and rotor assembly as per instructions in
6.1,6.9, 6.10 & 6.11.
6.12.2 Disconnect the wiring connectors off the heater plate and motor (mark motor wire
location). To release the motor connections push a fine blade screwdriver down
alongside the wiring connection to release the locking barb on the terminal.
6.12.3 Disconnect the rotor position sensor from the motor housing.
6.12.4 While lifting the tab on the locking ring, rotate the ring anticlockwise until it comes
free of tub tabs.
6.12.5 This also releases the motor housing from the locking ring.
6.12.6 Holding the pump housing on the motor assembly lift the locking ring, heating
plate and motor clear of the tub.
6.12.7 The suction pipe of the drain molding will slide out of the tub drain area.
6.12.8 You may now lift the locking ring clear of the motor assembly. This will allow the
heater plate and motor assembly to come apart
6.12.9 Be careful of the two 'O' rings which seal between the motor assembly and heater
plate and the heater plate and tub, these and the tub sealing area must be clean
and put in the correct place before reassembly takes place.
6.12.10 Check both the drain cuff 'O' ring and suction pipe 'O' ring for deformation and
damage. Lubricate and if necessary replace 'O' rings before reassembly.
6.12.11 Reassemble in reverse manner ensuring all locking ring tabs are engaged.
- 42 -