Fisher & Paykel DS6021 Service Manual page 32

Table of Contents

Advertisement

U2
The tub drawer has been
sensed as open during
the cycle or the exhaust
valve is open circuit.
Is the drawer
open?
Yes
No
Check the
Shut the drawer.
microswitch is
working in
diagnostics.
OK
Not OK
Check the
mechanical
Replace the
operation of the
microswitch.
the slides.
OK
Not OK
Test the exhaust
valve for an open
Adjust the slides.
circuit.
Note : Tub home microswitch is located on the rear
of the left slide runner and is connected in series with
the exhaust valve.