This section describes an example of when the disk 1 and disk 5 failed.
Click [Start] → [Administrative Tools] → [Computer Management]. The [Computer Management] window
1.
appears.
2.
Click [Disk Management] under [Storage] in the console tree. An
example in this figure shows that one of the mirrored disks in
which Drives E and F are included is broken. Some disks are
indicated as "Unknown disk." However, they may be indicated
differently depending on the error type. Even in such cases,
failed disks can be recovered by following the steps below:
3.
Remove the hard disks of disk 1 and disk 5.
4.
Right-click a volume that has "!", and remove mirror.
5.
After checking to see the "Missing" disk is selected, click
[Remove mirror]. At Drive (F), [Mirror] and [Failed
Redundant] will change to [Simple] and [Healthy].
NovaScale R620 User Guide