On-screen error message
0613 COM A configuration
change
0614 COM A config, error -
device disable
0B28 Unsupported
Processor detected on
Processor 1
0B29 Unsupported
Processor detected on
Processor 2
0B60 DIMM group #1 has
been disabled
0B61 DIMM group #2 has
been disabled
0B62 DIMM group #3 has
been disabled
0B70 The error occurred
during temperature
sensor reading
0B71 System Temperature
out of the range
0B74 The error occurred
during voltage sensor
reading
0B75 System voltage out of
the range
0B80 BMC Memory Test
Failed
0B81 BMC Firmware Code
Area CRC check failed
0B82 BMC core Hardware
failure
0B83 BMC IBF or OBF
check
failed
0B8A BMC SEL area full
0B8B BMC progress check
timeout
0B8C BMC command
access failed
0B8D Could not redirect the
console - BMC Busy
0B8E Could not redirect the
console - BMC Error
0B8F Could not redirect the
console – BMC
parameter Error -
0B90 BMC Platform
Information Area
corrupted
0B91 BMC update firmware
corrupted
0B92 Internal Use Area of
BMC FRU corrupted
0B93 BMC SDR Repository
empty
0B94 IPMB signal lines do
not respond
0B95 BMC FRU device
failure
NovaScale R620 User Guide
Cause
COM A configuration is faulty.
Device constructing COM A is
faulty.
Unsupported CPU is mounted.
Unsupported CPU is mounted.
DIMM is faulty.
I2C pass is faulty.
Sensor is faulty.
Temperature is abnormal.
Fan is abnormal.
I2C pass is faulty.
Sensor is faulty.
Voltage is abnormal.
RMC device is faulty.
RMC device is faulty.
There is no space to write
system event logs.
BMC check is suspended.
BMC command access failed.
Console cannot be redirected
(BMC is busy).
BMC is faulty.
Configuration is faulty.
BMC device is faulty.
Data within SROM is faulty.
SDR data is faulty.
SMC is faulty.
NVRAM within BMC is faulty.
Action
If restarting does not help after resetting the setting
to default by using BIOS setup, replace the CPU/IO
module.
Check the supported CPU and replace it. If this does
not help, replace the CPU/IO module.
Replace DIMM Group#1.
Replace DIMM Group#2.
Replace DIMM Group#3.
Replace the part that relevant sensor is mounted.
Check if fan is faulty or clogging has occurred. If
there is no problem, replace CPU/IO module.
Replace the part that relevant sensor is mounted.
If turning AC power off and on does not help, replace
the CPU/IO module.
Replace the CPU/IO module or ft Remote
Management Card (option).
Replace the CPU/IO module or ft Remote
Management Card (option).
Clear system event logs after saving them.
Replace the CPU/IO module or ft Remote
Management Card (option).
Replace the CPU/IO module or ft Remote
Management Card (option).
There is a possibility that the BMC was busy and
could not respond. Restart the server again.
Replace the CPU/IO module or ft Remote
Management Card (option).
Configure the console redirection by using BIOS
setup.
Replace the CPU/IO module or ft Remote
Management Card (option).
If updating SDR does not help, replace the CPU/IO
module or ft Remote Management Card (option).
Replace the CPU/IO module or a centre plane after
determining where IPMB error has occurred based
on OS information.
Replace the CPU/IO module or ft Remote
Management Card (option).