On-screen error message
0B96 BMC SDR Repository
failure
0B97 BMC SEL device
failure
0B98 BMC RAM test error
0B99 BMC Fatal hardware
error
0B9A BMC not responding
0B9B Private I2C bus not
responding
0B9C BMC internal
exception
0B9D BMC A/D timeout error
0B9E SDR repository corrupt
0B9F SEL corrupt
0BA0 SDR/PIA mismatched.
SDR, PIA must be
updated.
0BB0 SMBIOS - SROM data
read error
0BB1 SMBIOS - SROM data
checksum bad
0BC0 POST detected
start-up failure of 1st
Processor
0BC1 POST detected
start-up failure of 2nd
Processor
8120 Unsupported DIMM
detected in DIMM
group #1
8121 Unsupported DIMM
detected in DIMM group #
8122 Unsupported DIMM
detected in DIMM group
#3
8130 Mismatch DIMM detected
in DIMM group#1
8131 Mismatch DIMM detected
in DIMM group#2
8132 Mismatch DIMM detected
in DIMM group#3
8150 NVRAM Cleared By
Jumper
8151 Password Cleared By
Jumper
8160 Mismatch Processor
Speed detected on
Processor 1
8161 Mismatch Processor
Speed detected on
Processor 2
8170 Processor 1 not
operating at intended
frequency.
8171 Processor 2 not
operating at intended
frequency
NovaScale R620 User Guide
Cause
SDR repository within BMC is
faulty.
SEL repository within BMC is
faulty.
BMC RAM is faulty.
BMC FPGA is faulty.
BMC device is faulty.
I2C bus is faulty.
BMC device is faulty.
SDR data is faulty.
SEL repository within BMC is
faulty.
SDR and PIA data do not
match.
I2C bus is faulty.
SROM is faulty.
BMC is faulty.
Data within SROM is faulty.
CPU is faulty.
Unsupported DIMM is
mounted.
DIMM group do not match.
CMOS clear jumper is
mounted.
Password clear jumper is
mounted.
CPU frequency does not
match.
CPU frequency is incorrect.
CPU frequency is incorrect.
Action
If updating FPGA does not help, replace the CPU/IO
module or ft Remote Management Card (option).
Replace the CPU/IO module or ft Remote
Management Card (option).
Replace the part related to failed I2C bus.
Replace the CPU/IO module or ft Remote
Management Card (option).
If updating SDR does not help, replace the CPU/IO
module or ft Remote Management Card (option).
Replace the CPU/IO module or ft Remote
Management Card (option).
If updating SDR/PIA does not help, replace CPU/IO
module or ft Remote Management Card (option).
If turning AC power off and on does not help, replace
the CPU/IO module.
Replace the CPU.
Check supported DIMMs and replace the DIMM. If
replacing the DIMM does not help, replace the
CPU/IO module.
Turn off the DC power and change back the jumper
setting.
Check supported CPUs and replace the CPU. If
replacing the CPU does not help, replace CPU/IO
module.
Check supported CPUs and replace the CPU. If
replacing the CPU does not help, replace CPU/IO
module.